Literature DB >> 16967471

Anterior interosseous nerve conduction study: normative data.

Steve Vucic1, Con Yiannikas.   

Abstract

Neurophysiological techniques assessing anterior interosseous nerve (AIN) function and employing surface electrode recordings from the flexor pollicis longus (FPL), have been limited by technical difficulties. The aim of this study was to describe a surface electrode recording technique of investigating the AIN by recording compound muscle action potentials (CMAPs) from FPL. CMAP responses exhibited a negative onset, suggesting that they originated from FPL, and this was confirmed by needle recording. Normative data has been established that may prove useful in future studies assessing pathological involvement of the anterior interosseous nerve.

Entities:  

Mesh:

Year:  2007        PMID: 16967471     DOI: 10.1002/mus.20643

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  1 in total

1.  Pseudo-Anterior Interosseus Nerve Syndrome: A Case Report and a Review of Clinical Signs, Pathology and Functional Anatomy of the Precision Grip.

Authors:  Hassan Kesserwani
Journal:  Cureus       Date:  2021-05-22
  1 in total