Respiration-induced changes in tissue blood volume distal to occluded artery, measured by photoplethysmography.

Meir Nitzan, Igor Faib, Haim Friedman.   

Abstract

Photoplethysmography (PPG) measures the cardiac-induced fluctuations and other changes in tissue blood volume by light transmission measurement. In the current study, light transmission was simultaneously measured in the two index fingers of healthy subjects, while the brachial artery in the left arm was occluded by a pressure cuff, so that no PPG signal appeared in the left finger. Correlated respiratory-induced changes in the PPG baseline in the right hand and in the light transmission in the left hand were found, indicating respiratory-induced blood volume changes in the finger distal to the occluded artery. The blood volume changes under the PPG probe distal to the occluded artery are interpreted as transition of blood volume from small arteries into big veins, mediated by the sympathetic nervous system.

Mesh:

Year:  2006        PMID: 16965128     DOI: 10.1117/1.2236285

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  8 in total

1.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology.

Authors:  Juan C Ruiz-Rodríguez; Adolf Ruiz-Sanmartín; Vicent Ribas; Jesús Caballero; Alejandra García-Roche; Jordi Riera; Xavier Nuvials; Miriam de Nadal; Oriol de Sola-Morales; Joaquim Serra; Jordi Rello
Journal:  Intensive Care Med       Date:  2013-06-06       Impact factor: 17.440

2.  A New Wearable System for Home Sleep Apnea Testing, Screening, and Classification.

Authors:  Alessandro Manoni; Federico Loreti; Valeria Radicioni; Daniela Pellegrino; Luigi Della Torre; Alessandro Gumiero; Damian Halicki; Paolo Palange; Fernanda Irrera
Journal:  Sensors (Basel)       Date:  2020-12-08       Impact factor: 3.576

Review 3.  Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

Authors:  Peter H Charlton; Drew A Birrenkott; Timothy Bonnici; Marco A F Pimentel; Alistair E W Johnson; Jordi Alastruey; Lionel Tarassenko; Peter J Watkinson; Richard Beale; David A Clifton
Journal:  IEEE Rev Biomed Eng       Date:  2017-10-24

Review 4.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

5.  Multimodal Finger Pulse Wave Sensing: Comparison of Forcecardiography and Photoplethysmography Sensors.

Authors:  Emilio Andreozzi; Riccardo Sabbadini; Jessica Centracchio; Paolo Bifulco; Andrea Irace; Giovanni Breglio; Michele Riccio
Journal:  Sensors (Basel)       Date:  2022-10-06       Impact factor: 3.847

Review 6.  An Evaluation of Biometric Monitoring Technologies for Vital Signs in the Era of COVID-19.

Authors:  Christine Manta; Sneha S Jain; Andrea Coravos; Dena Mendelsohn; Elena S Izmailova
Journal:  Clin Transl Sci       Date:  2020-10-12       Impact factor: 4.689

7.  Breathing Rate Estimation from Head-Worn Photoplethysmography Sensor Data Using Machine Learning.

Authors:  Simon Stankoski; Ivana Kiprijanovska; Ifigeneia Mavridou; Charles Nduka; Hristijan Gjoreski; Martin Gjoreski
Journal:  Sensors (Basel)       Date:  2022-03-08       Impact factor: 3.576

8.  Spectral analysis of physiological brain pulsations affecting the BOLD signal.

Authors:  Lauri Raitamaa; Niko Huotari; Vesa Korhonen; Heta Helakari; Anssi Koivula; Janne Kananen; Vesa Kiviniemi
Journal:  Hum Brain Mapp       Date:  2021-05-26       Impact factor: 5.038

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.