Measurement of high energy x-ray beam penumbra with Gafchromic EBT radiochromic film.

Tsang Cheung1, Martin J Butson, Peter K N Yu.   

Abstract

High energy x-ray beam penumbra are measured using Gafchromic EBT film. Gafchromic EBT, due to its limited energy dependence and high spatial resolution provide a high level of accuracy for dose assessment in penumbral regions. The spatial resolution of film detector systems is normally limited by the scanning resolution of the densitometer. Penumbral widths (80%/20%) measured at Dmax were found to be 2.8, 3.0, 3.2, and 3.4 mm (+/- 0.2 mm) using 5, 10, 20, and 30 cm square field sizes, respectively, for a 6 MV linear accelerator produced x-ray beam. This is compared to 3.2 mm +/- 0.2 mm (Kodak EDR2) and 3.6 mm +/- 0.2 mm (Kodak X-Omat V) at 10 cm x 10 cm measured using radiographic film. Using a zero volume extrapolation technique for ionization chamber measurements, the 10 cm X 10 cm field penumbra at Dmax was measured to be 3.1 mm, a close match to Gafchromic EBT results. Penumbral measurements can also be made at other depths, including the surface, as the film does not suffer significantly from dosimetric variations caused by changing x-ray energy spectra. Gafchromic EBT film provides an adequate measure of penumbral dose for high energy x-ray beams.

Entities:  

Mesh:

Year:  2006        PMID: 16964868     DOI: 10.1118/1.2218318

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

2.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

3.  Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers.

Authors:  S Xu; C Xie; Z Ju; X Dai; H Gong; L Wang; J Yang
Journal:  Biomed Imaging Interv J       Date:  2010-04-01

4.  Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application.

Authors:  S-T Chiu-Tsao; Mf Chan
Journal:  Biomed Imaging Interv J       Date:  2009-10-01

5.  Comparison of Epson scanner quality for radiochromic film evaluation.

Authors:  Hani Alnawaf; Peter K N Yu; Martin Butson
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

6.  Comparative evaluation of modern dosimetry techniques near low- and high-density heterogeneities.

Authors:  Eyad A Alhakeem; Sami AlShaikh; Anatoly B Rosenfeld; Sergei F Zavgorodni
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

7.  Evaluation and Validation of IBA I'MatriXX Array for Patient-Specific Quality Assurance of TomoTherapy®.

Authors:  N V N Madhusudhana Sresty; A Krishnam Raju; B Nagarjuna Reddy; V C Sahithya; Yakub Mohmd; G Deleep Kumar; T Anil Kumar; Tasneem Rushdi; S Aparna; G Durga Prasad; Harjot Kaur Bajwa
Journal:  J Med Phys       Date:  2019 Jul-Sep

8.  Radiation transmission, leakage and beam penumbra measurements of a micro-multileaf collimator using GafChromic EBT film.

Authors:  Olivia Amanda García-Garduño; Miguel Angel Celis; José Manuel Lárraga-Gutiérrez; Sergio Moreno-Jiménez; Arnulfo Martínez-Dávalos; Mercedes Rodríguez-Villafuerte
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.