Literature DB >> 16963672

Continuous noninvasive measurement of pulsus paradoxus complements medical decision making in assessment of acute asthma severity.

James Rayner1, Flor Trespalacios, Jason Machan, Vijaya Potluri, George Brown, Linda M Quattrucci, Gregory D Jay.   

Abstract

BACKGROUND: Pulsus paradoxus (PP) is a pathophysiologic parameter that is indicative of asthma severity. The ability of PP to categorize acutely asthmatic patients in accordance with the earlier National Asthma Education and Prevention Program (NAEPP) expert panel report 1 guidelines was determined.
METHODS: An arterial tonometric BP monitor, which was interfaced to an analog-digital converter, executed a periodic amplitude analysis algorithm, which computed PP in real time. The PP measurement was compared to the criterion standard of emergency physicians in determining the hospital admission vs hospital discharge disposition following the NAEPP standardized treatment. Receiver operating characteristics (ROCs) were calculated, and the PP threshold, which maximized sensitivity and specificity, was identified. In a separate laboratory investigation, PP was induced in a healthy volunteer by inspiration through a fixed resistance. Plethysmographic waveform changes, induced by PP, were measured by a second analog-to-digital converter that was connected to a pulse oximeter.
RESULTS: A total of 79 patients were enrolled in the study, of whom 63 met a priori inclusion criteria and had uninterrupted data acquisition. The mean PP for patients who were appropriately discharged from the hospital was 9.1 mm Hg (95% confidence interval [CI], 7.3 to 10.9 mm Hg) and differed from the PP of 17.6 mm Hg (95% CI, 13.5 to 21.8; p < 0.001) for patients admitted to the hospital/relapsed. The sensitivity and specificity for physician disposition were 0.83 and 0.89, respectively, and for PP values were 0.78 and 0.78, respectively. The Wilcoxon area under the ROC curve was 0.82 (95% CI, 0.64 to 0.99) following treatment. The risk ratio was 5.32 for hospital admission among patients with a PP of > 11.3 mm Hg. Changes in the photoplethysmography peak height were correlated to PP from the BP monitor by a regression line with a slope of 0.01 V/mm Hg.
CONCLUSIONS: Continuous PP can aid in determining disposition among emergency department (ED) patients with acute asthma. ED physicians equipped with a PP monitor would be able to objectify the work of breathing and would more closely adhere to NAEPP guidelines. The possibility that a PP detection algorithm could reside in a pulse oximeter warrants further investigation.

Entities:  

Mesh:

Year:  2006        PMID: 16963672     DOI: 10.1378/chest.130.3.754

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  4 in total

Review 1.  The asthma prediction rule to decrease hospitalizations for children with asthma.

Authors:  Donald H Arnold; Marion R Sills; Colin G Walsh
Journal:  Curr Opin Allergy Clin Immunol       Date:  2016-06

2.  Pulse Oximeter Plethysmograph Estimate of Pulsus Paradoxus as a Measure of Acute Asthma Exacerbation Severity and Response to Treatment.

Authors:  Donald H Arnold; Li Wang; Tina V Hartert
Journal:  Acad Emerg Med       Date:  2016-02-17       Impact factor: 3.451

3.  Noninvasive assessment of asthma severity using pulse oximeter plethysmograph estimate of pulsus paradoxus physiology.

Authors:  Donald H Arnold; Cathy A Jenkins; Tina V Hartert
Journal:  BMC Pulm Med       Date:  2010-03-29       Impact factor: 3.317

4.  Pulsus paradoxus: an underused tool.

Authors:  G Bandinelli; A Lagi; P A Modesti
Journal:  Intern Emerg Med       Date:  2007-03       Impact factor: 3.397

  4 in total