Coonrad-Morrey total elbow replacement for primary and revision surgery: a 2- to 7.5-year follow-up study.

Alberto G Schneeberger1, Dominik C Meyer, Edward H Yian.   

Abstract

In this study, 23 patients were treated with the Coonrad-Morrey total elbow prosthesis for posttraumatic arthrosis (15 cases), acute distal humeral fracture (1 case), inflammatory arthritis (3 cases), and revision of another type of total elbow prosthesis (4 cases). After a mean follow-up of 4 years (range, 2-7.5 years) or at revision as a result of loosening or infection, 78% had a satisfactory outcome according to the Mayo Elbow Performance Score. Of the patients, 16 (70%) had no or mild pain and 7 had moderate to severe pain. The loosening rate was 17%. Possible risk factors for loosening were poor cementing and anterior coronoid impingement. Of the patients, 10 (43%) had complications and 7 of these (30%) required revision surgery. The Coonrad-Morrey total elbow prosthesis can lead to successful outcomes for difficult elbow pathologies. However, the complication rate was higher in our series than previously reported. Some technical aspects for use of this implant are outlined.

Entities:  

Mesh:

Year:  2006        PMID: 16963289     DOI: 10.1016/j.jse.2006.01.013

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  19 in total

1.  Bicolumnar 90-90 plating of low-energy distal humeral fractures in the elderly patient.

Authors:  Daniel F Leigey; Dana J Farrell; Peter A Siska; Ivan S Tarkin
Journal:  Geriatr Orthop Surg Rehabil       Date:  2014-09

2.  Linked semi-constrained total elbow prosthesis in chronic arthritis: results of 18 cases.

Authors:  Maurizio Corradi; Marco Frattini; Bruno Panno; Silvio Tocco; Francesco Pogliacomi
Journal:  Musculoskelet Surg       Date:  2010-05

3.  Total elbow replacement with the Coonrad-Morrey prosthesis: our medium to long-term results.

Authors:  R Maheshwari; S Vaziri; R H Helm
Journal:  Ann R Coll Surg Engl       Date:  2012-04       Impact factor: 1.891

Review 4.  [Endoprosthesis for the fractured elbow: uni- and bicompartmental alloarthroplasty of the humero-ulnar joint].

Authors:  O Weber; C Burger; G Stein; S Gravius; D C Wirtz; P H Pennekamp; C N Kraft; M Müller
Journal:  Unfallchirurg       Date:  2010-12       Impact factor: 1.000

Review 5.  Distal humeral hemiarthroplasty: indications, results, and complications. A systematic review.

Authors:  John Dunn; Nicholas Kusnezov; Miguel Pirela-Cruz
Journal:  Hand (N Y)       Date:  2014-12

Review 6.  Indications and outcome in total elbow arthroplasty: A systematic review.

Authors:  Vasileios Samdanis; Gopikanthan Manoharan; Robert W Jordan; Adam C Watts; Paul Jenkins; Rohit Kulkarni; Michael Thomas; Amar Rangan; Stuart M Hay
Journal:  Shoulder Elbow       Date:  2019-09-12

7.  Revision total elbow arthroplasty with the linked Coonrad-Morrey total elbow arthroplasty: a retrospective study of twenty procedures.

Authors:  Hans Christian Plaschke; Theis Thillemann; Anne Kathrine Belling-Sørensen; Bo Olsen
Journal:  Int Orthop       Date:  2013-02-19       Impact factor: 3.075

8.  [Primary endoprosthetic replacement of fractured elbow in elderly patients].

Authors:  O Weber; C Burger; K Kabir; D C Wirtz; H Goost
Journal:  Unfallchirurg       Date:  2009-09       Impact factor: 1.000

9.  [Primary total elbow replacement for complex intra-articular distal humerus fractures].

Authors:  E Kraus; R Harstall; N Borisch; D Weber
Journal:  Unfallchirurg       Date:  2009-08       Impact factor: 1.000

Review 10.  Scoping review: Diagnosis and management of periprosthetic joint infection in elbow arthroplasty.

Authors:  A C Watts; A D Duckworth; I A Trail; J Rees; M Thomas; A Rangan
Journal:  Shoulder Elbow       Date:  2018-07-27