Alberto G Schneeberger1, Dominik C Meyer, Edward H Yian.
Abstract
In this study, 23 patients were treated with the Coonrad-Morrey total elbow prosthesis for posttraumatic arthrosis (15 cases), acute distal humeral fracture (1 case), inflammatory arthritis (3 cases), and revision of another type of total elbow prosthesis (4 cases). After a mean follow-up of 4 years (range, 2-7.5 years) or at revision as a result of loosening or infection, 78% had a satisfactory outcome according to the Mayo Elbow Performance Score. Of the patients, 16 (70%) had no or mild pain and 7 had moderate to severe pain. The loosening rate was 17%. Possible risk factors for loosening were poor cementing and anterior coronoid impingement. Of the patients, 10 (43%) had complications and 7 of these (30%) required revision surgery. The Coonrad-Morrey total elbow prosthesis can lead to successful outcomes for difficult elbow pathologies. However, the complication rate was higher in our series than previously reported. Some technical aspects for use of this implant are outlined.Entities:
Mesh:
Year: 2006 PMID: 16963289 DOI: 10.1016/j.jse.2006.01.013
Source DB: PubMed Journal: J Shoulder Elbow Surg ISSN: 1058-2746 Impact factor: 3.019