Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: a method for molecular imaging and targeted drug delivery.

Kullervo Hynynen1, Nathan McDannold, Natalia Vykhodtseva, Scott Raymond, Ralph Weissleder, Ferenc A Jolesz, Nickolai Sheikov.   

Abstract

OBJECT: The goal of this study was to explore the feasibility of using low-frequency magnetic resonance (MR) image-guided focused ultrasound as a noninvasive method for the temporary disruption of the blood-brain barrier (BBB) at targeted locations.
METHODS: Rabbits were placed inside a clinical 1.5-tesla MR imaging unit, and sites in their brains were targeted for 20-second burst sonications (frequency 260 kHz). The peak pressure amplitude during the burst varied between 0.1 and 0.9 MPa. Each sonication was performed after an intravenous injection of an ultrasound contrast agent (Optison). The disruption of the BBB was evaluated with the aid of an injection of an MR imaging contrast agent (MAG-NEVIST). Additional tests involving the use of MION-47, a 20-nm magnetic nanoparticle contrast agent, were also performed. The animals were killed at different time points between 3 minutes and 5 weeks postsonication, after which light or electron microscopic evaluation was performed. The threshold for BBB disruption was approximately 0.2 MPa. More than 80% of the brain sites sonicated showed BBB disruption when the pressure amplitude was 0.3 MPa; at 0.4 MPa, this percentage was greater than 90%. Tissue necrosis, ischemia, and apoptosis were not found in tissue in which the pressure amplitude was less than 0.4 MPa; however, in a few areas of brain tissue erythrocytes were identified outside blood vessels following exposures of 0.4 MPa or higher. Survival experiments did not show any long-term adverse events.
CONCLUSIONS: These results demonstrate that low-frequency ultrasound bursts can induce local, reversible disruption of the BBB without undesired long-term effects. This technique offers a potential noninvasive method for targeted drug delivery in the brain aided by a relatively simple low-frequency device.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16961141     DOI: 10.3171/jns.2006.105.3.445

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  128 in total

1.  Ultrasound-mediated tumor imaging and nanotherapy using drug loaded, block copolymer stabilized perfluorocarbon nanoemulsions.

Authors:  Natalya Rapoport; Kweon-Ho Nam; Roohi Gupta; Zhongao Gao; Praveena Mohan; Allison Payne; Nick Todd; Xin Liu; Taeho Kim; Jill Shea; Courtney Scaife; Dennis L Parker; Eun-Kee Jeong; Anne M Kennedy
Journal:  J Control Release       Date:  2011-01-26       Impact factor: 9.776

2.  Investigation of standing-wave formation in a human skull for a clinical prototype of a large-aperture, transcranial MR-guided focused ultrasound (MRgFUS) phased array: an experimental and simulation study.

Authors:  Junho Song; Aki Pulkkinen; Yuexi Huang; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2011-10-28       Impact factor: 4.538

Review 3.  Ultrasound enhanced drug delivery to the brain and central nervous system.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

4.  Magnetic resonance monitoring of focused ultrasound/magnetic nanoparticle targeting delivery of therapeutic agents to the brain.

Authors:  Hao-Li Liu; Mu-Yi Hua; Hung-Wei Yang; Chiung-Yin Huang; Po-Chun Chu; Jia-Shin Wu; I-Chou Tseng; Jiun-Jie Wang; Tzu-Chen Yen; Pin-Yuan Chen; Kuo-Chen Wei
Journal:  Proc Natl Acad Sci U S A       Date:  2010-08-09       Impact factor: 11.205

Review 5.  Therapeutic strategies to improve drug delivery across the blood-brain barrier.

Authors:  Tej D Azad; James Pan; Ian D Connolly; Austin Remington; Christy M Wilson; Gerald A Grant
Journal:  Neurosurg Focus       Date:  2015-03       Impact factor: 4.047

6.  Effect of Frequency and Focal Spacing on Transcranial Histotripsy Clot Liquefaction, Using Electronic Focal Steering.

Authors:  Tyler Gerhardson; Jonathan R Sukovich; Aditya S Pandey; Timothy L Hall; Charles A Cain; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2017-07-14       Impact factor: 2.998

7.  Mechanisms of the increase in the permeability of the blood-tumor barrier obtained by combining low-frequency ultrasound irradiation with small-dose bradykinin.

Authors:  Chun-yi Xia; Zhen Zhang; Yi-xue Xue; Ping Wang; Yun-hui Liu
Journal:  J Neurooncol       Date:  2009-02-22       Impact factor: 4.130

8.  Cavitation-enhanced nonthermal ablation in deep brain targets: feasibility in a large animal model.

Authors:  Costas D Arvanitis; Natalia Vykhodtseva; Ferenc Jolesz; Margaret Livingstone; Nathan McDannold
Journal:  J Neurosurg       Date:  2015-09-18       Impact factor: 5.115

Review 9.  Magnetic resonance-guided focused ultrasound: a new technology for clinical neurosciences.

Authors:  Ferenc A Jolesz; Nathan J McDannold
Journal:  Neurol Clin       Date:  2013-11-08       Impact factor: 3.806

Review 10.  Ultrasound-mediated blood-brain barrier disruption for targeted drug delivery in the central nervous system.

Authors:  Muna Aryal; Costas D Arvanitis; Phillip M Alexander; Nathan McDannold
Journal:  Adv Drug Deliv Rev       Date:  2014-01-22       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.