Literature DB >> 16960837

DNA sequencing and multiplex STR analysis on plastic microfluidic devices.

Yining Shi1.   

Abstract

The ability of plastic microfluidic devices with separation channel lengths of 6, 10 or 18 cm to perform high-quality and high-performance ssDNA analysis was evaluated. Specifically, four-color DNA sequencing separation of a terminator sequencing standard using replaceable, urea-denaturing linear polyacrylamide (LPA) solution as a sieving matrix, yielded read lengths of 410 bases in 15 min with base calling accuracy of 99.2% on a 6-cm device, and 640 bases in 35 min with accuracy of 98.0% on a 18-cm device. A two-color sizing analysis of four-locus (CSF1PO, TPOX, TH01, vWA) short tandem repeats (STRs) allelic ladder on a 10-cm device indicated a mean SD of +/- 0.08 base pairs (bp) between runs, and single bp resolution of spiked TH01 allele 9.3 (198 bp) from TH01 allele 10 (199 bp) of the CTTv ladder with R = 0.81. A four-color multiplex sizing analysis of three different AmpFlSTR allelic ladders consisting of nine loci (D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820) and gender alleles (Amelogenin) on a 10-cm device had a mean SD of +/- 0.15 bp between runs for sizing three loci, i.e., FGA, D18S51 and D3S818; alleles differing by 2 bp in size were resolved with resolutions close to baseline. This work demonstrates that plastic microfluidic devices are capable of quality sequencing and STR sizing comparable to that of glass devices of similar separation lengths.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16960837     DOI: 10.1002/elps.200600129

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  Polymer systems designed specifically for DNA sequencing by microchip electrophoresis: a comparison with commercially available materials.

Authors:  Christopher P Fredlake; Daniel G Hert; Brian E Root; Annelise E Barron
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

2.  Hydrophobically modified polyacrylamide block copolymers for fast, high-resolution DNA sequencing in microfluidic chips.

Authors:  Ryan E Forster; Thomas N Chiesl; Christopher P Fredlake; Corin V White; Annelise E Barron
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

3.  Modeling and Global Optimization of DNA separation.

Authors:  Max A Fahrenkopf; B Erik Ydstie; Tamal Mukherjee; James W Schneider
Journal:  Comput Chem Eng       Date:  2014-05-07       Impact factor: 3.845

4.  Integrated capture, concentration, polymerase chain reaction, and capillary electrophoretic analysis of pathogens on a chip.

Authors:  Nathaniel Beyor; Lina Yi; Tae Seok Seo; Richard A Mathies
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

5.  Ultrafast DNA sequencing on a microchip by a hybrid separation mechanism that gives 600 bases in 6.5 minutes.

Authors:  Christopher P Fredlake; Daniel G Hert; Cheuk-Wai Kan; Thomas N Chiesl; Brian E Root; Ryan E Forster; Annelise E Barron
Journal:  Proc Natl Acad Sci U S A       Date:  2008-01-09       Impact factor: 11.205

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.