A pilot study of the effects of Vivostat patient-derived fibrin sealant in reducing blood loss in primary hip arthroplasty.

Michael Rud Lassen1, Søren Solgaard, Anne Grete Kjersgaard, Claus Olsen, Bjørn Lind, Karen Mittet, Helle Coff Ganes.   

Abstract

A pilot study evaluated the effectiveness of Vivostat patient-derived fibrin sealant in reducing blood loss in patients who underwent primary hip arthroplasty. Eighty adult patients undergoing elective surgery were randomized to receive either Vivostat sealant or control (no additional hemostatic treatment). Patients allocated Vivostat sealant donated 120 mL of blood, which was then processed perioperatively to produce a fibrin sealant that was applied to the bleeding wound surfaces just before closure. Transfusion requirements, blood loss during surgery, drain volumes, and daily hematocrit and hemoglobin levels were measured. Hospitalization times, adverse events, and postoperative wound complications were also monitored. Blood loss during surgery and wound drainage volume was lower in the Vivostat group than in the control group, although the differences were not significantly different. Transfusion requirements (median, 270 mL of packed red blood cells) and hospitalization times (both median 7 days) were the same for both groups. No adverse events related to the use of Vivostat occurred. There were indications of a possible reduction in the incidence of postoperative wound oozing (15% vs 25%) and hematomas (6% vs 11%) with the use of Vivostat compared with the control group, although differences were not statistically significant. In conclusion, in this pilot study, use of Vivostat patient-derived fibrin in hip arthroplasty was not associated with a significant reduction in blood loss. Further studies, with larger numbers of patients, may be warranted to investigate a possible benefit of Vivostat in reducing postoperative wound complications.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16959690     DOI: 10.1177/1076029606291406

Source DB:  PubMed          Journal:  Clin Appl Thromb Hemost        ISSN: 1076-0296            Impact factor:   2.389


  6 in total

Review 1.  Blood conservation strategies in orthopedic surgeries: A review.

Authors:  Balaji Sambandam; Sahil Batra; Rajat Gupta; Nidhi Agrawal
Journal:  J Clin Orthop Trauma       Date:  2013-12-08

2.  Prevention of postoperative anemia in hip hemiarthroplasty for femoral neck fractures: comparison between local haemostatic agents.

Authors:  Antonio Ziranu; Cesare Meschini; Davide De Marco; Giuseppe Sircana; Maria Serena Oliva; Giusepp Rovere; Andrea Corbingi; Raffaele Vitiello; Giulio Maccauro; Enrico Pola
Journal:  Orthop Rev (Pavia)       Date:  2022-10-13

Review 3.  Fibrin sealant use for minimising peri-operative allogeneic blood transfusion.

Authors:  P A Carless; D A Henry; D M Anthony
Journal:  Cochrane Database Syst Rev       Date:  2003

4.  Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part I: Intracranial surgical procedure.

Authors:  Francesca Graziano; Francesco Certo; Luigi Basile; Rosario Maugeri; Giovanni Grasso; Flavia Meccio; Mario Ganau; Domenico G Iacopino
Journal:  Surg Neurol Int       Date:  2015-05-12

5.  Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.

Authors:  Francesca Graziano; Rosario Maugeri; Luigi Basile; Favia Meccio; Domenico Gerardo Iacopino
Journal:  Surg Neurol Int       Date:  2016-01-25

Review 6.  A Systematic Review and Meta-analysis of the Topical Administration of Fibrin Sealant in Total Hip Arthroplasty.

Authors:  Zhihu Zhao; Xinlong Ma; Jianxiong Ma; Xiaolei Sun; Fengbo Li; Jianwei Lv
Journal:  Sci Rep       Date:  2018-01-08       Impact factor: 4.379