Literature DB >> 16959185

Development of a sensitive and specific liquid chromatography/mass spectrometry method for the quantification of cucurbitacin I (JSI-124) in rat plasma.

Ommoleila Molavi1, Anooshirvan Shayeganpour, Vishwa Somayaji, Samar Hamdy, Dion R Brocks, Afsaneh Lavasanifar, Glen S Kwon, John Samuel.   

Abstract

PURPOSE: To develop a liquid chromatography/mass spectrometry (LC-MS) method for the quantitative analysis of cucurbitacin I (JSI-124), an anti-cancer inhibitor of the janus kinase 2/signal transducer and activator of transcription 3 (JAK2/STAT3) signaling pathway, in rat plasma samples.
METHODS: Standard samples of cucurbitacin I were prepared from a stock solution (1 mg/mL) in methanol. Internal standard (I.S.) was 4-hydroxybenzophenone. Extraction of cucurbitacin I and I.S. from rat plasma was performed using acetonitrile/dichloromethane. LC-MS analyses were performed using a Waters Micromass ZQ 4000 spectrometer, and chromatographic separation was achieved using a Waters XTerraMSC18 3.5 microm (2.1 x 50 mm) column as the stationary phase. The mobile phase consisting of a mixture of acetonitrile: water containing 1% formic acid with initial ratio of 20:80, employing a linear gradient to a final ratio of 40:60 v/v over 13 minutes, was delivered at a constant flow rate of 0.2 mL/min. The mass spectrometer was operated in negative ionization mode and analytes were quantified with single ion recording (SIR) at m/z 559 for cucurbitacin I and m/z 196.8 for I.S.
RESULTS: Calibration curves with r2 > 0.999 were constructed over the concentration range of 5-10000 ng/mL for the solution of cucurbitacin I in methanol and 10-1000 ng/mL for rat plasma samples. The extraction recoveries were 86 and 98% for 50 ng/mL and 1000 ng/mL plasma concentration of cucurbitacin I, respectively. The intra- and inter-day coefficients of variation were less than 15%, and mean intraday errors were less than 10% at plasma concentration extending from 10-1000 ng/mL.
CONCLUSION: The developed assay is sensitive, specific, reproducible and reliable for quantitative analysis of cucurbitacin I. Application in a pharmacokinetic assessment was proven in the rats given the drug.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16959185

Source DB:  PubMed          Journal:  J Pharm Pharm Sci        ISSN: 1482-1826            Impact factor:   2.327


  3 in total

1.  Nanoprecipitation is more efficient than emulsion solvent evaporation method to encapsulate cucurbitacin I in PLGA nanoparticles.

Authors:  Aws Alshamsan
Journal:  Saudi Pharm J       Date:  2013-12-14       Impact factor: 4.330

Review 2.  Use of cucurbitacins for lung cancer research and therapy.

Authors:  Min Liu; Qijia Yan; Bi Peng; Yuan Cai; Shuangshuang Zeng; Zhijie Xu; Yuanliang Yan; Zhicheng Gong
Journal:  Cancer Chemother Pharmacol       Date:  2021-04-06       Impact factor: 3.333

3.  Polymeric micelles for the solubilization and delivery of STAT3 inhibitor cucurbitacins in solid tumors.

Authors:  Ommoleila Molavi; Zengshuan Ma; Abdullah Mahmud; Aws Alshamsan; John Samuel; Raymond Lai; Glen S Kwon; Afsaneh Lavasanifar
Journal:  Int J Pharm       Date:  2007-06-26       Impact factor: 5.875

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.