Literature DB >> 16958688

Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols.

Ilser Turkyilmaz1, Lars Sennerby, Celal Tumer, Muhittin Yenigul, Mehmet Avci.   

Abstract

OBJECTIVES: The aim of this study was to compare the performance of two non-splinted implants used as retention for a mandibular overdenture when applying conventional or early loading protocols.
MATERIAL AND METHODS: Twenty edentulous patients were treated with two unsplinted and non-submerged implants (15 mm long, TiUnite RP, Brånemark System) in the anterior mandible. The patients were randomly allotted into two groups: (i) test group (Group A), in which the overdenture was connected 1 week after surgery, and (ii) control group (Group B), in which the overdenture was connected after 12 weeks of healing. Resonance frequency analyses (RFA) for implant stability measurements were performed at implant surgery and after 1, 3, 6, 9 and 12 months. Marginal bone levels were evaluated at implant surgery and after 6 and 12 months.
RESULTS: No implant from either group was lost and all implants showed less than 1 mm of marginal bone resorption during the first year. The mean implant stability quotient (ISQ) values at implant surgery were 76.2+/-2.8 for Group A and 75.6+/-4.5 for Group B. The 12-month measurements showed 76.4+/-2.5 ISQ and 76.4+/-2.8 ISQ for Groups A and B, respectively. There were no statistically significant changes between or within the groups with time. There were no differences in marginal bone loss, which was on average 0.3 mm for both groups after 1 year.
CONCLUSION: Although a limited number of patients were followed for 1 year only, the results of the present study indicate that early loading of two unsplinted 15 mm long implants with an overdenture does not negatively affect implant stability or marginal bone conditions when compared with implants subjected to 12 weeks of healing before loading.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16958688     DOI: 10.1111/j.1600-0501.2006.01261.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

Review 1.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

Review 2.  Implant loss and crestal bone loss in early loading versus delayed and immediate loading in edentulous mandibles. A systematic review and meta-analysis.

Authors:  Beatriz Pardal-Peláez; Javier Flores-Fraile; José-Luis Pardal-Refoyo; Javier Montero
Journal:  J Clin Exp Dent       Date:  2021-04-01

3.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

4.  Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis.

Authors:  Kenko Tanaka; Irena Sailer; Ryosuke Iwama; Kensuke Yamauchi; Shinnosuke Nogami; Nobuhiro Yoda; Tetsu Takahashi
Journal:  J Periodontal Implant Sci       Date:  2018-12-27       Impact factor: 2.614

5.  Masticatory performances and maximum occlusal forces of immediate and conventional loaded two-implant supported overdentures retained by magnetic attachments: preliminary study of randomized controlled clinical trial.

Authors:  Awutsadaporn Katheng; Manabu Kanazawa; Yuriko Komagamine; Anna Miyayasu; Yoko Uehara; Daisuke Sato; Shunsuke Minakuchi
Journal:  Int J Implant Dent       Date:  2021-06-29

6.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07

7.  Influence of bone density on implant stability parameters and implant success: a retrospective clinical study.

Authors:  Ilser Turkyilmaz; Edwin A McGlumphy
Journal:  BMC Oral Health       Date:  2008-11-24       Impact factor: 2.757

8.  Clinical efficacy of early loading versus conventional loading of dental implants.

Authors:  Yanfei Zhu; Xinyi Zheng; Guanqi Zeng; Yi Xu; Xinhua Qu; Min Zhu; Eryi Lu
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.