Literature DB >> 16957787

The effect of adding a stone base on the accuracy of working casts using different types of dental stone.

Khalid Al-Abidi1, Ayman Ellakwa.   

Abstract

AIM: Gypsum products are used for the preparation of stone casts of oral and maxillofacial structures and as important adjuncts to dental laboratory operations involved in the production of dental prostheses. The aim of this study was to determine the effect on the dimensional accuracy of a working cast of adding a stone base using different stone products. METHODS AND MATERIALS: A total of forty impressions of a mandibular dentoform were made. The impressions were dried with compressed air and stored at room temperature for 24 hours before pouring stone casts. The forty impressions were randomly divided into four groups of ten each. All forty impressions were poured once using one pre-weighed 140 Gm package of Silky Rock (SR) Type IV improved stone (Whip Mix Corporation, Louisville, KY, USA ) per impression. All working casts and the die setups were prepared according to the manufacturer's recommendations for pin placement (M.R. Dual pin and sleeve). Four different types of dental stone (II, III, and IV) and Flow Stone (FS) were used as bases for the working models. They were mixed according to the manufacturer's recommendations. The lower posterior teeth were flattened on the dentoform prior to taking the impressions. All were indexed using a mounted abrasive disc. Four teeth were selected as follows: 21, 28, 30, and 18. These represented A, B, C, and D landmarks, respectively. All measurements (five times for each specimen) were made with a Universal measuring microscope (Unitron Instruments, Inc., Bohemia, NY, USA). After the pre-sectioned measurements were recorded, the stone base was poured. A manual hand saw was used to section and fabricate removable dies for the mandibular landmarks A, B, C, and D. The dies were later seated and removed ten times to simulate the average amount of handling during laboratory procedures. Each die was carefully seated and measurements were made using the same technique as for the master model and unsectioned casts. Multivariate repeated measures analysis of variance (MANOVA) was used to test the difference in three different landmark distances (AB, AC, and AD) among the master model before and after sectioning of the working dies and among the four different base materials. Univariate analysis of variance (ANOVA) was conducted for each measurement, AB, AC, and AD to test the difference in landmark distances on the master model at pre sectioning and then at post sectioning using four different base materials. When there was a significant main effect (p < .05), the Student-Newman-Keul's (SNK) were used to test for pair wise comparison of means (P<0.05).
RESULTS: The results of the MANOVA indicated there was a significant difference in three landmark measurements on the master model before and after sectioning of the working dies for the four different base materials (F = 6.60, p = 0.0001). In addition there was a significant difference in three landmark measurements on the master model at: (1) pre sectioning (p = 0.0001), (2) between the master model and SR material (p = 0.0002), (3) between the master model and Laboratory Plaster (LP) material (p = 0.0001), (4) between the master model and Quick Stone (QS) material (p = 0.0001), and (5) between the master model and FS material (p = 0.0001).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16957787

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  3 in total

1.  Impact of surface roughness of gypsum materials on adaptation of zirconia cores.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Sa-Hak Kim
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

2.  Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.

Authors:  Stephania Caroline Rodolfo Silva; Aion Mangino Messias; Filipe de Oliveira Abi-Rached; Raphael Freitas de Souza; José Maurício Dos Santos Nunes Reis
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

3.  Dimensional accuracy of stone casts obtained with multiple pours into the same mold.

Authors:  Valdimar da Silva Valente; Artêmio Luiz Zanetti; Pedro Paulo Feltrin; Ricardo Tatsuo Inoue; Carmem Dolores Vilarinho Soares de Moura; Luiz Evaldo de Moura Pádua
Journal:  ISRN Dent       Date:  2012-12-24
  3 in total