Literature DB >> 16955045

Cervical catheter tip placement for intrathecal baclofen administration.

Todd D McCall1, Joel D MacDonald.   

Abstract

OBJECTIVE: Intrathecal baclofen can reduce congenital and posttraumatic spasticity. Traditionally, the catheter tip for baclofen delivery is placed in a low thoracic position, which can result in a lumbar-to-cisternal cerebrospinal fluid baclofen concentration gradient. We investigated whether more rostral catheter placement was technically feasible, safe, and able to control upper extremity spasticity.
METHODS: The records of 48 patients with a baclofen pump were reviewed retrospectively to evaluate the safety and efficacy of cervically placed intrathecal catheters for baclofen administration. Twenty-three patients had a catheter located in a cervical position and 25 had a catheter in a thoracic position (control group). Complications, including baclofen overdose, mechanical failures, and infections, were noted. Pre- and postoperative Ashworth scores were determined by a physical therapist using a standardized protocol.
RESULTS: The mean duration of the follow-up period was 10 months. The groups were not significantly different in patient age, baclofen dose, or duration of follow-up, but differed somewhat in the causes of spasticity. For patients with a cervical catheter tip position, upper extremity Ashworth scores decreased significantly from 4.0 +/- 0.8 (standard deviation) preoperatively to 3.0 +/- 0.9 postoperatively (P = 0.003). In both groups, lower extremity spasticity was significantly reduced. Postoperatively, one patient with a cervical catheter developed aspiration pneumonia, possibly because of sedation. Other complications included hardware infections, mechanical malfunctions, and pseudomeningoceles.
CONCLUSION: In this series, placement of intrathecal baclofen catheters in the cervical region resulted in equal control of spasticity in the upper and lower extremities and did not increase complications related to the catheter position.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16955045     DOI: 10.1227/01.NEU.0000227570.40402.77

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  12 in total

1.  Intrathecal baclofen therapy for spasticity of cerebral origin--does the position of the intrathecal catheter matter?

Authors:  Gnanamurthy Sivakumar; Yoong Yap; Mekidm Tsegaye; Michael Vloeberghs
Journal:  Childs Nerv Syst       Date:  2010-03-20       Impact factor: 1.475

Review 2.  Imaging evaluation of intrathecal baclofen pump-catheter systems.

Authors:  A C Miracle; M A Fox; R N Ayyangar; A Vyas; S K Mukherji; D J Quint
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-28       Impact factor: 3.825

Review 3.  Intrathecal baclofen for childhood hypertonia.

Authors:  A Leland Albright
Journal:  Childs Nerv Syst       Date:  2007-06-29       Impact factor: 1.475

4.  Intrathecal Baclofen therapy in Germany: Proceedings of the IAB-Interdisciplinary Working Group for Movement Disorders Consensus Meeting.

Authors:  D Dressler; S Berweck; A Chatzikalfas; M Ebke; B Frank; S Hesse; M Huber; J K Krauss; K-H Mücke; A Nolte; H-D Oelmann; P W Schönle; M Schmutzler; H Pickenbrock; C Van der Ven; N Veelken; M Vogel; T Vogt; F Adib Saberi
Journal:  J Neural Transm (Vienna)       Date:  2015-07-16       Impact factor: 3.575

5.  Effect of intrathecal baclofen concentration on spasticity control: case series.

Authors:  April Saval; Anthony E Chiodo
Journal:  J Spinal Cord Med       Date:  2008       Impact factor: 1.985

Review 6.  Intrathecal pumps.

Authors:  Shawn Belverud; Alon Mogilner; Michael Schulder
Journal:  Neurotherapeutics       Date:  2008-01       Impact factor: 7.620

Review 7.  Role of Catheter's Position for Final Results in Intrathecal Drug Delivery. Analysis Based on CSF Dynamics and Specific Drugs Profiles.

Authors:  De Andres Jose; Perotti Luciano; Villanueva Vicente; Asensio Samper Juan Marcos; Fabregat-Cid Gustavo
Journal:  Korean J Pain       Date:  2013-10-02

8.  Plain radiography in patients treated with intrathecal drug delivery using an implantable pump device.

Authors:  Elmar M Delhaas; Biswadjiet S Harhangi; Sander P G Frankema; Frank J P M Huygen; Aad van der Lugt
Journal:  Insights Imaging       Date:  2017-08-24

9.  A numerical investigation of intrathecal isobaric drug dispersion within the cervical subarachnoid space.

Authors:  Per Thomas Haga; Giulia Pizzichelli; Mikael Mortensen; Miroslav Kuchta; Soroush Heidari Pahlavian; Edoardo Sinibaldi; Bryn A Martin; Kent-Andre Mardal
Journal:  PLoS One       Date:  2017-03-15       Impact factor: 3.240

10.  Intrathecal catheter implantation decreases cerebrospinal fluid dynamics in cynomolgus monkeys.

Authors:  Mohammadreza Khani; Audrey Q Fu; Joshua Pluid; Christina P Gibbs; John N Oshinski; Tao Xing; Gregory R Stewart; Jillynne R Zeller; Bryn A Martin
Journal:  PLoS One       Date:  2020-12-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.