Literature DB >> 16950612

Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein.

Zong Dai1, Simona Serban, Huangxian Ju, Nabil El Murr.   

Abstract

A rapid one-step flow/stop-flow injection amperometric immunoassay for alpha-fetoprotein (AFP) using a novel home-produced electrochemical sensor was proposed. The sensor was prepared using layer-by-layer adsorption of positively charged poly(allylamine) (PAA) and negatively charged hydroxymethyl ferrocene on a screen-printed electrode (SPE). The electrochemistry of the immobilized ferrocene moieties showed a surface-controlled electrode process. Based on an electrochemical enzyme-linked immunoassay with the immobilized ferrocene moieties as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP)-labeled anti-AFP antibody, a calibration curve with two linear ranges from 5 to 20 and 20 to 150 ng ml-1 and a detection limit of 2 ng ml-1 for AFP determination was obtained under the optimized conditions of 0.891 ml min-1 flow rate, 20 microl injection volume and +25 mV applied potential. The sensor showed good repeatability and reproducibility and retained more than 95% of its original signal after 15 days of storage. The proposed method eliminated the need for washing and addition of any substrate or mediator. The complete assay could be handled in less than 25 min with a one-step injection of a 40 microl sample solution. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16950612     DOI: 10.1016/j.bios.2006.07.034

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode.

Authors:  Ai-Cheng Lee; Guodong Liu; Chew-Kiat Heng; Swee-Ngin Tan; Tit-Meng Lim; Yuehe Lin
Journal:  Electroanalysis       Date:  2008-08-05       Impact factor: 3.223

Review 2.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

3.  A sensitive label-free amperometric immunosensor for alpha-fetoprotein based on gold nanorods with different aspect ratio.

Authors:  Chunyang Zhou; Dali Liu; Lin Xu; Qingling Li; Jian Song; Sai Xu; Ruiqing Xing; Hongwei Song
Journal:  Sci Rep       Date:  2015-04-24       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.