OBJECTIVE: We evaluated the current clinical experience of temporary inferior vena cava (IVC) filter placement and its related complications. METHODS: From January 2000 to December 2005, we enrolled 33 patients (8 men and 25 women) who underwent percutaneous insertion of a temporary IVC filter in the Department of Vascular Surgery of Tokyo University Hospital. Deep vein thrombosis (DVT) was proven in 78.8% of the patients. The indications for filter insertion were contraindication to anticoagulation therapy (9.1%), thrombolytic therapy (12.1%), perioperative prophylactic implantation (84.8%), pregnancy with DVT (3.0%), and prophylactic implantation in the absence of DVT (15.2%). A Neuhaus Protect was used in 13 patients, and an Antheor was used in 20 patients. RESULTS: The mean +/- SD duration of filter placement was 10.6 +/- 7.0 days. There was no case of pulmonary embolism during filter protection and retraction. Filter thrombosis (capture of thrombus) was observed in four patients (12.1%), who then received additional thrombolytic therapy. Thrombi were dissolved by thrombolysis in three, one of whom had replacement with a permanent filter. The thrombus was not dissolved in one patient and was removed under venotomy at the insertion site. Major filter-related complications occurred in nine patients (27.3%), including filter dislocation in four patients (12.1%), catheter fracture in three (9.1%), and catheter-related infection in one (3.0%). In a patient with giant ovarian cancer, the IVC was nearly occluded with massive thrombus around the filter 2 days after operation, and the vena cava was then ligated under open laparotomy. No patients died during filter protection and retraction. CONCLUSIONS: Temporary IVC filters were effective for the prevention of fatal pulmonary embolism. However, our experience of a high incidence of complications related to temporary filters suggests that this device has limited indications and supports the need for innovative design of temporary filters.
OBJECTIVE: We evaluated the current clinical experience of temporary inferior vena cava (IVC) filter placement and its related complications. METHODS: From January 2000 to December 2005, we enrolled 33 patients (8 men and 25 women) who underwent percutaneous insertion of a temporary IVC filter in the Department of Vascular Surgery of Tokyo University Hospital. Deep vein thrombosis (DVT) was proven in 78.8% of the patients. The indications for filter insertion were contraindication to anticoagulation therapy (9.1%), thrombolytic therapy (12.1%), perioperative prophylactic implantation (84.8%), pregnancy with DVT (3.0%), and prophylactic implantation in the absence of DVT (15.2%). A Neuhaus Protect was used in 13 patients, and an Antheor was used in 20 patients. RESULTS: The mean +/- SD duration of filter placement was 10.6 +/- 7.0 days. There was no case of pulmonary embolism during filter protection and retraction. Filter thrombosis (capture of thrombus) was observed in four patients (12.1%), who then received additional thrombolytic therapy. Thrombi were dissolved by thrombolysis in three, one of whom had replacement with a permanent filter. The thrombus was not dissolved in one patient and was removed under venotomy at the insertion site. Major filter-related complications occurred in nine patients (27.3%), including filter dislocation in four patients (12.1%), catheter fracture in three (9.1%), and catheter-related infection in one (3.0%). In a patient with giant ovarian cancer, the IVC was nearly occluded with massive thrombus around the filter 2 days after operation, and the vena cava was then ligated under open laparotomy. No patients died during filter protection and retraction. CONCLUSIONS: Temporary IVC filters were effective for the prevention of fatal pulmonary embolism. However, our experience of a high incidence of complications related to temporary filters suggests that this device has limited indications and supports the need for innovative design of temporary filters.
Authors: Sri G Thrumurthy; Abeyratne H M P Anuruddha; Merrenna I M De Zoysa; Dharmabandhu N Samarasekera Journal: BMC Surg Date: 2011-01-06 Impact factor: 2.102
Authors: Brian Shuch; Ryan Falbo; Fabio Parisi; Adebowale Adeniran; Yuval Kluger; Harriet M Kluger; Lucia B Jilaveanu Journal: Biomed Res Int Date: 2015-09-13 Impact factor: 3.411