Literature DB >> 1694765

Iliopelvic lymphoscintigraphy with 99mTc-dextran in malignant lymphoma.

S Naldöken1, M T Ercan, C F Bekdik.   

Abstract

99mTc-Dextran (99mTc-D) was evaluated as an iliopelvic lymphoscintigraphic agent in 49 patients with malignant lymphoma and the results were compared with ultrasound (US), lymphangiography (LA) and CT where available. Scintigrams were obtained by a gamma camera at 2 h postinjection and evaluated by comparing opposite sides. In 29 of 49 patients, normal lymphoscintigrams of excellent quality, deliniating the iliopelvic and paraaortic lymph nodes bilaterally were obtained. In 20 patients lymphoscintigraphy (LS) was positive. US was performed in 46 patients, 20 had positive and 26 negative findings. There was one false positive and one false negative in LS compared to US. Ten patients had LA and 3 had CT. These results were in complete agreement with LS. There was also a positive correlation between the clinical stages and the results of LS. This study showed that 99mTc-D is an excellent radiopharmaceutical for the visualization of the lymph system with high correlation with other imaging modalities.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1694765     DOI: 10.1007/bf01146852

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Evaluation of 99mTc-dextran as a lymphoscintigraphic agent in rabbits.

Authors:  M T Ercan; M Schneidereit; R Senekowitsch; H Kriegel
Journal:  Eur J Nucl Med       Date:  1985

2.  Parasternal lymphoscintigraphy using 99Tcm-dextran.

Authors:  B Karayalcin; G Aras; G Erbay; M T Ercan
Journal:  Nucl Med Commun       Date:  1988-09       Impact factor: 1.690

3.  Clinical evaluation of lymph node scanning utilizing colloidal gold 198.

Authors:  I Kazem; J Antoniades; L W Brady; D S Faust; M N Croll; D Lightfoot
Journal:  Radiology       Date:  1968-05       Impact factor: 11.105

4.  Clinical comparison of 99mTc-labeled preformed phytate colloid and sulfur colloid: concise communication.

Authors:  A Arzoumanian; L Rosenthall; H Seto
Journal:  J Nucl Med       Date:  1977-02       Impact factor: 10.057

5.  Interstitial radiocolloid iliopelvic lymphoscintigraphy: technique, anatomy and clinical application.

Authors:  G N Ege; B J Cummings
Journal:  Int J Radiat Oncol Biol Phys       Date:  1980-11       Impact factor: 7.038

6.  Technetium-99m stannous phytate as an imaging agent for lymph nodes.

Authors:  A Alavi; M M Staum; B F Shesol; P H Bloch
Journal:  J Nucl Med       Date:  1978-04       Impact factor: 10.057

7.  Comparison of 99Tcm lymphoscintigraphy and lymphangiography in patients with malignant lymphomas.

Authors:  E Taaning; I Holten; L Specht; J Jørgensen
Journal:  Acta Radiol Diagn (Stockh)       Date:  1985 Jan-Feb

8.  Comparison as a lymphoscintigraphic agent between 99Tcm dextran and 99Tcm antimony sulphide colloid.

Authors:  N Juma; T Andrey; G N Ege
Journal:  Br J Radiol       Date:  1985-04       Impact factor: 3.039

9.  Lymphoscintigraphy with Tc-99m-labeled dextran.

Authors:  E Henze; H R Schelbert; J D Collins; A Najafi; J R Barrio; L R Bennett
Journal:  J Nucl Med       Date:  1982-10       Impact factor: 10.057

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.