Literature DB >> 16945381

Analysis of estrogens in environmental waters using polymer monolith in-polyether ether ketone tube solid-phase microextraction combined with high-performance liquid chromatography.

Yi Wen1, Bing-Sheng Zhou, Ying Xu, Shi-Wei Jin, Yu-Qi Feng.   

Abstract

A simple, rapid and sensitive on-line method for simultaneous determination of four endocrine disruptors (17beta-estradiol, estriol, bisphenol A and 17alpha-ethinylestradiol) in environmental waters was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). A poly(acrylamide-vinylpyridine-N,N'-methylene bisacrylamide) monolith, synthesized inside a polyether ether ketone (PEEK) tube, was selected as the extraction medium. To achieve optimum extraction performance, several parameters were investigated, including extraction flow-rate, extraction time, and pH value, inorganic salt and organic solvent content of the sample matrix. By simply filtered with nylon membrane filter and adjusting the pH of samples to 6.0 with phosphoric acid, the sample solution then could be directly injected into the device for extraction. Low detection limits (S/N=3) and quantification limits (S/N=10) of the proposed method were achieved in the range of 0.006-0.10 ng/mL and 0.02-0.35 ng/mL from spiked lake waters, respectively. The calibration curves of four endocrine disruptors showed good linearity ranging from quantification limits to 50 ng/mL with a linear coefficient R(2) value above 0.9913. Good method reproducibility was also found by intra- and inter-day precisions, yielding the RSDs less than 12 and 9.8%, respectively. Finally, the proposed method was successfully applied to the determination of these compounds in several environmental waters.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16945381     DOI: 10.1016/j.chroma.2006.08.049

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  Reproductive drugs and environmental contamination: quantum, impact assessment and control strategies.

Authors:  Harpreet Kaur; Madhu Bala; Gulshan Bansal
Journal:  Environ Sci Pollut Res Int       Date:  2018-07-23       Impact factor: 4.223

2.  Smart Titanium Wire Used for the Evaluation of Hydrophobic/Hydrophilic Interaction by In-Tube Solid Phase Microextraction.

Authors:  Yuping Zhang; Ning Wang; Zhenyu Lu; Na Chen; Chengxing Cui; Xinxin Chen
Journal:  Molecules       Date:  2022-04-06       Impact factor: 4.411

3.  Development of Simultaneous Derivative Spectrophotometric and HPLC Methods for Determination of 17-Beta-Estradiol and Drospirenone in Combined Dosage Form.

Authors:  Zeynep Aydoğmuş; Ece Merve Yılmaz; Sevgi Yörüsün; Samet Akpınar
Journal:  Int Sch Res Notices       Date:  2015-04-27

Review 4.  High Performance Liquid Chromatography (HPLC) with Fluorescence Detection for Quantification of Steroids in Clinical, Pharmaceutical, and Environmental Samples: A Review.

Authors:  Fatima Hameedat; Sahar Hawamdeh; Soraya Alnabulsi; Aref Zayed
Journal:  Molecules       Date:  2022-03-10       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.