Literature DB >> 16945262

[Spirometry in primary care in Navarre, Spain].

Javier Hueto1, Pilar Cebollero, Idoya Pascal, José Antonio Cascante, Víctor Manuel Eguía, Francisco Teruel, Manuel Carpintero.   

Abstract

OBJECTIVE: To analyze the use and quality of spirometry in primary care settings in Navarre, Spain. PATIENTS AND METHODS: A questionnaire was completed simultaneously by professionals responsible for spirometry in all of the primary health care centers in Navarre. Data were collected on availability, model of spirometer, frequency of use, calibration, methods, personnel responsible for testing, and training of personnel. Then, baseline spirometry without a bronchodilator test was performed in 171 patients in their primary health care center and then the test was repeated on the same day in a hospital pneumology department. Spirometry was supervised by 2 pneumologists who jointly assessed the acceptability of the flow-volume curves. The quality of spirometry was assessed according to the recommendations of the American Thoracic Society and the interpretation of spirometry results according to the criteria of the Spanish Society of Pulmonology and Thoracic Surgery (SEPAR).
RESULTS: A total of 90.9% of primary health care centers in Navarre have a spirometer, although 22% of those spirometers have never been used. Only 2 centers performed between 10 and 20 spirometry tests per week and none performed more than 20. In 96% of primary health care centers the spirometers were not regularly calibrated. The professionals who performed spirometry were not dedicated for that task in 51.2% of cases, and the mean period of supervised training was 10 hours. When comparisons were made between the mean values obtained in the primary care centers and the pneumology department, statistically significant differences were detected for forced vital capacity (P < .0001) and forced expiratory volume in the first second (P = .0002). Significant differences were also found between the flow-volume curves performed in the 2 different care settings for the initial and end portions of the curve as well as for the slope. The criteria for reproducibility recommended by the American Thoracic Society were not met in 76% of cases for forced vital capacity and 39.7% of cases for forced expiratory volume in the first second. Incorrect functional diagnosis occurred in 39.7% of spirometry tests and there was a tendency in the primary care settings to falsely diagnose patterns as restrictive and to inadequately classify the severity of obstruction.
CONCLUSIONS: Despite the fact that spirometers are available in the majority of primary health care centers in Navarre, we found a marked underuse of these devices and little compliance with recommendations for the use of spirometry. Furthermore, the quality of the measurements performed in this care setting was very low.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16945262     DOI: 10.1016/s1579-2129(06)60541-7

Source DB:  PubMed          Journal:  Arch Bronconeumol        ISSN: 0300-2896            Impact factor:   4.872


  11 in total

1.  [Quality of spirometry tests done in primary care units in the province of Gipuzkoa].

Authors:  José Manuel Martínez Eizaguirre; María Isabel Irizar Aranburu; Cristina Estirado Vera; Iñaki Berraondo Zabalegui; Ricardo San Vicente Blanco; Elisa Aguirre Canflanca
Journal:  Aten Primaria       Date:  2008-05       Impact factor: 1.137

Review 2.  Diagnosis of asthma in adults.

Authors:  Alan G Kaplan; Meyer S Balter; Alan D Bell; Harold Kim; R Andrew McIvor
Journal:  CMAJ       Date:  2009-09-21       Impact factor: 8.262

3.  Case finding for chronic obstructive pulmonary disease in people attending long-term condition clinics in primary care.

Authors:  Dmg Halpin; S Holmes; J Calvert; D McInerney
Journal:  Chron Respir Dis       Date:  2016-07-08       Impact factor: 2.444

4.  Why is spirometry underused in the diagnosis of the breathless patient: a qualitative study.

Authors:  Nicola J Roberts; Susan F Smith; Martyn R Partridge
Journal:  BMC Pulm Med       Date:  2011-06-16       Impact factor: 3.317

5.  FUMEPOC: early detection of chronic obstructive pulmonary disease in smokers.

Authors:  Vicente Gil-Guillén; Domingo Orozco-Beltrán; Concepcion V Carratala Munuera; Carlos Plaza-Sirvent; Patricia Lorca-Amorrich; Adriana López-Pineda; María P Vela-Troncoso; Juan J Soler; Manuel Yarza-Cañellas; Antonio Fernández; Luis Rosado-Bretón; Carmen Olivares-Bautista; Alejandro Muñoz-Fernández
Journal:  BMC Public Health       Date:  2011-05-31       Impact factor: 3.295

6.  [Accesibility and use of spirometry in primary care centers in Catalonia].

Authors:  M Antònia Llauger; Alba Rosas; Felip Burgos; Elena Torrente; Ricard Tresserras; Joan Escarrabill
Journal:  Aten Primaria       Date:  2014-04-24       Impact factor: 1.137

7.  Evaluation of current knowledge, awareness and practice of spirometry among hospital -based Nigerian doctors.

Authors:  Olufemi O Desalu; Olusegun A Busari; Cajetan C Onyedum; Fatai K Salawu; Olusegun A Obateru; Kelechukwu C Nwogu; Alakija K Salami
Journal:  BMC Pulm Med       Date:  2009-12-14       Impact factor: 3.317

8.  Asthma and COPD in primary health care, quality according to national guidelines: a cross-sectional and a retrospective study.

Authors:  Siw Carlfjord; Malou Lindberg
Journal:  BMC Fam Pract       Date:  2008-06-19       Impact factor: 2.497

9.  COPD Underdiagnosis and Misdiagnosis in a High-Risk Primary Care Population in Four Latin American Countries. A Key to Enhance Disease Diagnosis: The PUMA Study.

Authors:  Alejandro Casas Herrera; Maria Montes de Oca; Maria Victorina López Varela; Carlos Aguirre; Eduardo Schiavi; José R Jardim
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

10.  [Healthcare resources for asthma management at primary care level: Asthmabarometer Project].

Authors:  Jesús Molina París; Enrique Mascarós Balaguer; Daniel Ocaña Rodríguez; Pere Simonet Aineto; Carlos Campo Sien
Journal:  Aten Primaria       Date:  2018-12-24       Impact factor: 1.137

View more