Literature DB >> 16944894

Delta34S measurements of sulfur by multicollector inductively coupled plasma mass spectrometry.

Robert Clough1, Peter Evans, Tim Catterick, E Hywel Evans.   

Abstract

An accurate and precise method for the determination of delta34S measurements by multicollector inductively coupled plasma mass spectrometry has been developed. Full uncertainty budgets, taking into consideration all the uncertainties of the measurement process, have been calculated. The technique was evaluated by comparing measured values with a range of isotopically enriched sulfur solutions prepared by gravimetric addition of a 34S spike. The gravimetric and measured results exhibited a correlation of R2 >0.999. Repeat measurements were also made after adding Na (up to 420 microg g(-1)) and Ca (up to 400 microg g(-1)) salts to the sulfur standard. No significant deviations in the delta34S values were observed. The Russell correction expression (Ingle, C.; Sharp, B.; Horstwood, M.; Parrish, R.; Lewis, D. J. J. Anal. At. Spectrom. 2003, 18, 219) was used to correct for mass bias on the 34S/32S isotope amount ratio from the mass bias observed for the 30Si/28Si isotope amount ratio. Consistent compensation for instrumental mass bias was achieved. Resolution of the measured delta34S values was better than 1 per thousand after consideration of all uncertainty components. The technique was evaluated for practical applications by measurement of delta34S for a range of mineral waters by pneumatic nebulization sample introduction and the analysis of genuine and counterfeit pharmaceuticals using both laser ablation sample introduction and liquid chromatography. For the former two cases polyatomic interferences were resolved by operating the MC-ICPMS in medium resolution, while for the chromatographic analyses polyatomic interferences were minimized by the use of a membrane desolvator, allowing the instrument to be operated at a resolution of 400.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16944894     DOI: 10.1021/ac060875h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Method development for on-line species-specific sulfur isotopic analysis by means of capillary electrophoresis/multicollector ICP-mass spectrometry.

Authors:  Sebastian Faßbender; Katerina Rodiouchkina; Frank Vanhaecke; Björn Meermann
Journal:  Anal Bioanal Chem       Date:  2020-07-01       Impact factor: 4.142

2.  MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane.

Authors:  Ondrej Hanousek; Torsten W Berger; Thomas Prohaska
Journal:  Anal Bioanal Chem       Date:  2015-10-05       Impact factor: 4.142

3.  Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr.

Authors:  Monika Horsky; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Bioanal Chem       Date:  2016-01       Impact factor: 4.142

4.  The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

Authors:  Ondrej Hanousek; Marion Brunner; Daniel Pröfrock; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Methods       Date:  2016-09-23       Impact factor: 2.896

Review 5.  Facing Counterfeit Medications in Sexual Medicine. A Systematic Scoping Review on Social Strategies and Technological Solutions.

Authors:  Andrea Sansone; Béatrice Cuzin; Emmanuele A Jannini
Journal:  Sex Med       Date:  2021-10-04       Impact factor: 2.491

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.