Normal and variant appearances of the adult epididymis and vas deferens on high-resolution sonography.

Thierry Puttemans1, Annick Delvigne, Daniel Murillo.   

Abstract

PURPOSE: To describe the appearance, anatomic position, and size of the normal adult epididymis and vas deferens using high-resolution sonography.
METHODS: The sonographic appearance, anatomic position, and size of the epididymal head (EH), epididymal body (EB), epididymo-deferential loop (EDL), and vas deferens (VD) were evaluated in 112 consecutive infertile men (infertile group), and the data were compared with those from 84 consecutive men without history of infertility (reference group).
RESULTS: Compared with the testis, the EH was isoechoic, the EB hypoechoic, and the VD anechoic. In 88.4% of cases in the infertile group and 97.6% of cases in the reference group, the EH was located above the upper pole of the testis, with the EB lateral to the testis and the EDL below the lower pole of the testis. In 9% of cases in the infertile group and 6% of cases in the reference group, the EB was located posterior to the body of the testis, with the EDL inverted and the VD anterior to the ET. In 11.6% of cases in the infertile group and 2.4% of cases in the reference group, the epididymis was inverted, with the EH located below the lower pole of the testis. The mean (+/-SD) normal sizes were as follows: EH, 7.6 +/- 1.6 mm; EB, 3.2 +/- 0.8 mm; EDL, 7.7 +/- 1.3 mm; VD, 1.9 +/- 0.2 mm. No statistically significant differences in size were found between the 2 groups.
CONCLUSIONS: We describe the normal and variant appearance, position, and size of the adult epididymis and VD on high-resolution sonography.

Entities:  

Mesh:

Year:  2006        PMID: 16944482     DOI: 10.1002/jcu.20257

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  3 in total

1.  Do positional variations of epididymis affect infertility?

Authors:  Emre Can Akınsal; Numan Baydilli; Abdullah Demirtaş; Oğuz Ekmekçioğlu
Journal:  Turk J Urol       Date:  2018-01-05

2.  Application of optical coherence tomography and high-frequency ultrasound imaging during noninvasive laser vasectomy.

Authors:  Christopher M Cilip; Mohamad E Allaf; Nathaniel M Fried
Journal:  J Biomed Opt       Date:  2012-04       Impact factor: 3.170

3.  Ultrasonography in Diagnosis of Congenital Absence of the Vas Deferens.

Authors:  Liang Li; Chaozhao Liang
Journal:  Med Sci Monit       Date:  2016-07-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.