Literature DB >> 16941726

An extensive study on isosorbide-5-mononitrate acid adducts for quantification in human plasma using liquid chromatography/electrospray ionization tandem mass spectrometry and its application to bioequivalence sample analysis.

Deepak S Jain1, Gunta Subbaiah, Mallika Sanyal, Pranav S Shrivastav, Usha Pal, Shailesh Ghataliya, Abhijeet Kakad, Jignesh Bhatt, Vaneet Munjal, Heena Patel, Sapna Shah.   

Abstract

A rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the determination of isosorbide-5-mononitrate (5-ISMN), used in the treatment of angina pectoris, in human plasma is described. The quantification of 5-ISMN was performed via stable acetate adduct formation with a high relative abundance. The plasma filtrate obtained after solid-phase extraction (SPE), using a polymer based, hydrophilic-lipophilic balanced (HLB) cartridge, was submitted directly to reversed-phase high-performance liquid chromatography separation followed by ESI and detection of the resulting ions using triple-quadrupole mass spectrometry in selected reaction monitoring (SRM) mode. There was no significant matrix effect on the analysis. For validation of the method, the recovery of the free analyte response was compared to that obtained from an optimized extraction method. The analyte stability was examined under conditions mimicking the sample storage, handling, and analytical procedures. The extraction procedure yielded extremely clean extracts with a recovery of 95.51% and 93.98% for iossorbide-5-mononitrate and topiramate (internal standard (IS)), respectively. The calibration curves were linear for the dynamic range of 10.0 to 1000.0 ng/mL with a correlation coefficient r > or = 0.9985. The intra-assay and inter-assay precision for the samples at the lower limit of quantification (LLOQ) were 9.02 and 13.30%, respectively. The intra-assay accuracies at LLOQ, LQC, MQC and HQC levels varied from 98.13 to 118.15, 102.34 to 105.21, 100.69 to 109.68, and 95.76 to 102.92%, respectively, while the inter-assay accuracies ranged from 93.10 to 118.15, 93.03 to 107.04, 86.97 to 109.68 and 86.18 to 105.85%, respectively, at these levels. The method is rugged and fast with a total run time of 2 min. The method was successfully applied for a bioequivalence study in 24 human subject samples after oral administration of 60 mg extended release (ER) formulations. Copyright 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16941726     DOI: 10.1002/rcm.2684

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Preclincial testing of sorafenib and RAD001 in the Nf(flox/flox) ;DhhCre mouse model of plexiform neurofibroma using magnetic resonance imaging.

Authors:  Jianqiang Wu; Eva Dombi; Edwin Jousma; R Scott Dunn; Diana Lindquist; Beverly M Schnell; Mi-Ok Kim; Aerang Kim; Brigitte C Widemann; Timothy P Cripe; Nancy Ratner
Journal:  Pediatr Blood Cancer       Date:  2011-02-11       Impact factor: 3.167

2.  Determination of Isosorbide-5-Mononitrate in Human Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Bioequivalence Study.

Authors:  Yinping Zhou; Aijing Liu; Ranran Jia; Mengyi Wu; Ni Wu; Chunyan Liu; Zhihui Han; Haitang Hu; Hongyun Wang; Qing He
Journal:  J Anal Methods Chem       Date:  2020-07-17       Impact factor: 2.193

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.