Impression techniques and misfit-induced strains on implant-supported superstructures: an in vitro study.

Murat C Cehreli1, Kivanç Akça.   

Abstract

The purpose of this study was to compare misfit-induced strains on implant-supported superstructures fabricated by two impression techniques and two different elastomeric impression materials. A master cast hosting four Straumann implants was constructed. On this cast, a total of 21 implant-level impressions were made by the direct technique using a polyether impression material and synOcta screwed aluminum impression caps (PE-D), and by the indirect technique using polyether (PE-IN) or polyvinylsiloxane impression material (VPS-IN) with snap-on impression caps and synOcta plastic positioning cylinders. Two casts were randomly selected from each group of seven, and a total of four screw-retained superstructures, supported by either two or four implants (one of each type on both casts), were cast in a gold alloy for each group. Linear strain gauges were bonded on the superstructures, and misfit-induced strains were recorded during superstructure connection on each of the working casts and on the master cast using a data acquisition system and corresponding software at a sample rate of 10 kHz. Connection on the implants in the master cast increased strains considerably on most of the superstructures, in comparison with strain gradients measured when the superstructures were connected on the casts from which they were fabricated (P <.05). The differences in strain amplitude between connection on the cast from which the superstructure was fabricated and on the master cast were higher for superstructures fabricated by PE-D than for those fabricated by PE-IN and VPS-IN. The snap-on indirect impression technique for Straumann implants leads to acceptable superstructures, regardless of the impression material used.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16939020

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  7 in total

1.  Impression of multiple implants using photogrammetry: description of technique and case presentation.

Authors:  David Peñarrocha-Oltra; Rubén Agustín-Panadero; Leticia Bagán; Beatriz Giménez; María Peñarrocha
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-07-01

2.  Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations.

Authors:  Abbass Fallah Tafti; Mahnaz Hatami; Foroughsadat Razavi; Behnaz Ebadian
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

3.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

4.  Three-dimensional accuracy of different impression techniques for dental implants.

Authors:  Mohammadreza Nakhaei; Azam S Madani; Azizollah Moraditalab; Hamidreza Rajati Haghi
Journal:  Dent Res J (Isfahan)       Date:  2015 Sep-Oct

5.  The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap.

Authors:  Abolfazl Saboury; Hamid Neshandar Asli; Zahra Dalili Kajan
Journal:  J Dent (Shiraz)       Date:  2017-12

6.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20

7.  Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study.

Authors:  G Parameshwari; B Chittaranjan; N Sudhir; C-K Anulekha-Avinash; M Taruna; M Ramureddy
Journal:  J Clin Exp Dent       Date:  2018-04-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.