Literature DB >> 16938104

A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants.

I Turkyilmaz1.   

Abstract

The aim of this study was to determine primary stability and insertion torque of Brånemark System implants placed in the anterior mandible, and to evaluate a possible correlation between primary stability and insertion torque. Thirty edentulous patients were treated with 60 Brånemark System implants using a one-stage technique. The insertion torque values of all implants were recorded with the Osseocare equipment. Immediately after implant placement, each implant was connected to the transducer of an Osstell machine to measure the primary implant stability. The average insertion torque and resonance frequency values were 41.5 +/- 5.8 and 74.1 +/- 3.8 for 30 implants. The correlation between insertion torque and resonance frequency values indicated a statistical significance (P < 0.001). The difference between mean insertion torque values for female and male patients was statistically significant (P < 0.001). No significant difference (P > 0.05) was found between younger and older patients with mean insertion torque values of 43.1 +/- 4.7 and 40.1 +/- 6.5 respectively. The results of this study showed a strong correlation between the primary stability and insertion torque values of Brånemark System TiUnite MKIII implants at the time of implant placement.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16938104     DOI: 10.1111/j.1365-2842.2006.01631.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  12 in total

1.  Immediate loading of implants in the edentulous mandible: a multicentre study.

Authors:  Paulo Esteves Pinto Faria; Bárbara Masalskas; Anders Heyden; Lars Rasmusson; Luiz Antonio Salata
Journal:  Oral Maxillofac Surg       Date:  2016-09-16

2.  Influence of cortical bone anchorage on the primary stability of dental implants.

Authors:  Anne Kelly de Oliveira Nicolau Mantovani; Ivete Aparecida de Mattias Sartori; Luciana Reis Azevedo-Alanis; Rodrigo Tiossi; Flávia Noemy Gasparini Kiatake Fontão
Journal:  Oral Maxillofac Surg       Date:  2018-06-06

3.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

4.  Minimally Invasive Alveolar Ridge Preservation Utilizing an In Situ Hardening β-Tricalcium Phosphate Bone Substitute: A Multicenter Case Series.

Authors:  Minas D Leventis; Peter Fairbairn; Ashish Kakar; Angelos D Leventis; Vasileios Margaritis; Walter Lückerath; Robert A Horowitz; Bappanadu H Rao; Annette Lindner; Heiner Nagursky
Journal:  Int J Dent       Date:  2016-04-14

5.  The relationship between the bone characters obtained by CBCT and primary stability of the implants.

Authors:  Masahiro Wada; Yasutane Tsuiki; Tohru Suganami; Kazunori Ikebe; Motofumi Sogo; Ikuhisa Okuno; Yoshinobu Maeda
Journal:  Int J Implant Dent       Date:  2015-02-12

6.  A One-year Follow-up Study of a Tapered Hydrophilic Implant Design Using Various Placement Protocols in the Maxilla.

Authors:  Jakob Zwaan; Leonardo Vanden Bogaerde; Herman Sahlin; Lars Sennerby
Journal:  Open Dent J       Date:  2016-12-09

7.  Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants.

Authors:  Peter Andersson; Luca Pagliani; Damiano Verrocchi; Stefano Volpe; Herman Sahlin; Lars Sennerby
Journal:  Int J Dent       Date:  2019-04-01

8.  Bioceramic cement in the filling of bone defects in rats.

Authors:  Christiano Cândido Zerbinatti; Daniela Francescato Veiga; Monique Amanda Bastista Oliveira; Fiorita Gonzales Lopes Mundim; Rodrigo Machado Pereira; Francisco Azevedo; Taylor Brandão Schnaider; José Dias da Silva Neto
Journal:  Acta Cir Bras       Date:  2019-08-19       Impact factor: 1.388

9.  The effect of implant length and diameter on the primary stability in different bone types.

Authors:  Hamidreza Barikani; Shadab Rashtak; Soolmaz Akbari; Samareh Badri; Niloufar Daneshparvar; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2013-09-30

10.  An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

Authors:  Pedro Hernández-Cortés; Alberto Monje; Pablo Galindo-Moreno; Andrés Catena; Inmaculada Ortega-Oller; José Salas-Pérez; Francisco Mesa; Rafael Gómez-Sánchez; Mariano Aguilar; David Aguilar; Francisco O'Valle
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.