An intraosseous infusion device designed for the prehospital administration of hypertonic saline-dextran solutions was evaluated by resuscitating hemorrhaged conscious sheep. Eight animals underwent 2 hours of hemorrhagic hypotension (50 mm Hg, bled volume = 43 +/- 7 ml/kg). This was followed by the intraosseous infusion of 200 ml (4-5 ml/kg) of 7.5% NaCl-6% dextran 70 into the bone marrow of the sternum. Results were compared to seven control animals (bled volume = 31 +/- 6 ml/kg) resuscitated through a central venous catheter. Despite the small volumes infused, mean arterial blood pressure and cardiac output were rapidly normalized in both groups by 10 minutes post resuscitation (p less than 0.01). Plasma sodium concentration increased an average of 12 mEq/L and plasma volume was rapidly expanded regardless of route. The metabolic acidosis of hemorrhagic shock was rapidly corrected, pulmonary pressures remained normal, and hypoxemia did not occur after intraosseous resuscitation. The device provided safe and rapid vascular access via the sternal bone marrow space. The use of intraosseous infusion of hypertonic saline dextran solutions via the sternal bone marrow may allow prehospital rescuers to consistently incorporate fluid replacement therapy into 'scoop and run' policies by avoiding the time delays associated with failures in IV access.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1693696     DOI: 10.1097/00005373-198907000-00038

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  5 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

2.  Technique for upgauging peripheral venous cannulae in volume resuscitation.

Authors:  M Harvey; Vijay Thumma; Grant Cave
Journal:  Emerg Med J       Date:  2007-05       Impact factor: 2.740

3.  Performance and longevity of a novel intraosseous device in a goat (Capra hircus) model.

Authors:  Erin E Jackson; T Clay Ashley; Karen F Snowden; Vincent C Gresham; Christine M Budke; Bunita M Eichelberger; Destiny A Taylor
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-05       Impact factor: 1.232

4.  [Intraosseous infusion for adults].

Authors:  B A Leidel; C Kirchhoff
Journal:  Chirurg       Date:  2008-04       Impact factor: 0.955

5.  Is the intraosseous access route fast and efficacious compared to conventional central venous catheterization in adult patients under resuscitation in the emergency department? A prospective observational pilot study.

Authors:  Bernd A Leidel; Chlodwig Kirchhoff; Viktoria Bogner; Julia Stegmaier; Wolf Mutschler; Karl-Georg Kanz; Volker Braunstein
Journal:  Patient Saf Surg       Date:  2009-10-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.