Literature DB >> 16936058

Microbiosensors for measurement of microbially available dissolved organic carbon: sensor characteristics and preliminary environmental application.

Marion Köster1, Christian G Gliesche, Rainer Wardenga.   

Abstract

Microbial respiration-based microbiosensors used for quantification of available dissolved organic carbon (ADOC) instantaneously respired by microorganisms are described. The sensing membranes contained aerobic seawater microorganisms immobilized in a polyurethane hydrogel. Molecular investigations revealed that the bacterial strain used was most closely related to Staphylococcus warneri. This strain was characterized by low substrate selectivity, which was reflected in the response to various mono- and disaccharides, short-chain fatty acids, and amino acids, as determined using Biolog microplates. Specific emphasis was placed on critically assessing biosensor functioning that was affected by preconditioning of the selected bacterial strain, chemical and geometric properties of the sensing membrane (e.g., composition, permeability, and thickness), and the distribution, biomass, and physiological state of immobilized cells, as well as the exposure conditions (e.g., temperature and nutrient supply). The sensors revealed that there was a linear response up to a glucose concentration of 500 microM depending on the type, characteristics, and recent history of the sensors. The detection limit of the sensors was equivalent to about 6 to 10 microM glucose. The 90% response time ranged from 1 to 5 min. Generally, the response of the biosensors became weaker with time. The shelf lives of individual sensors were up to 2 weeks. Measurements based on optical ADOC microbiosensors revealed that in photoautotrophically dominated sandy coastal sediments, the pool sizes and turnover of ADOC were regulated by the photosynthetic activity of benthic microalgae and microbial aerobic respiration. A large increase in ADOC production was observed shortly after the microphytobenthic primary production reached the maximum value at midday, whereas ADOC was consumed by microbial respiration during the night.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16936058      PMCID: PMC1636147          DOI: 10.1128/AEM.00641-06

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  23 in total

1.  Electrochemical biosensors: recommended definitions and classification.

Authors:  D R Thévenot; K Toth; R A Durst; G S Wilson
Journal:  Biosens Bioelectron       Date:  2001-01       Impact factor: 10.618

2.  The Use of Whole-Cell Biosensors to Detect and Quantify Compounds or Conditions Affecting Biological Systems.

Authors:  L.H. Hansen; S.J. Sørensen
Journal:  Microb Ecol       Date:  2001-12       Impact factor: 4.552

3.  A Microscale NO(3)(-) Biosensor for Environmental Applications.

Authors:  L H Larsen; T Kjær; N P Revsbech
Journal:  Anal Chem       Date:  1997-09-01       Impact factor: 6.986

4.  Immobilization of bacteria and Saccharomyces cerevisiae in poly(tetrafluoroethylene) membranes.

Authors:  F W Hyde; G R Hunt; L A Errede
Journal:  Appl Environ Microbiol       Date:  1991-01       Impact factor: 4.792

5.  Use of an oxygen-insensitive microscale biosensor for methane to measure methane concentration profiles in a rice paddy.

Authors:  L R Damgaard; N P Revsbech; W Reichardt
Journal:  Appl Environ Microbiol       Date:  1998-03       Impact factor: 4.792

6.  Design and application of a biosensor for monitoring toxicity of compounds to eukaryotes.

Authors:  R P Hollis; K Killham; L A Glover
Journal:  Appl Environ Microbiol       Date:  2000-04       Impact factor: 4.792

7.  Complete nucleotide sequence of a 16S ribosomal RNA gene from Escherichia coli.

Authors:  J Brosius; M L Palmer; P J Kennedy; H F Noller
Journal:  Proc Natl Acad Sci U S A       Date:  1978-10       Impact factor: 11.205

8.  Bacterium-based NO2- biosensor for environmental applications.

Authors:  Michael Nielsen; Lars Hauer Larsen; Mike S M Jetten; Niels Peter Revsbech
Journal:  Appl Environ Microbiol       Date:  2004-11       Impact factor: 4.792

9.  Development and testing of a bacterial biosensor for toluene-based environmental contaminants.

Authors:  B M Willardson; J F Wilkins; T A Rand; J M Schupp; K K Hill; P Keim; P J Jackson
Journal:  Appl Environ Microbiol       Date:  1998-03       Impact factor: 4.792

10.  A microsensor for nitrate based on immobilized denitrifying bacteria.

Authors:  L H Larsen; N P Revsbech; S J Binnerup
Journal:  Appl Environ Microbiol       Date:  1996-04       Impact factor: 4.792

View more
  3 in total

1.  New and fast method to quantify respiration rates of bacterial and plankton communities in freshwater ecosystems by using optical oxygen sensor spots.

Authors:  Mareike Warkentin; Heike M Freese; Ulf Karsten; Rhena Schumann
Journal:  Appl Environ Microbiol       Date:  2007-08-31       Impact factor: 4.792

2.  Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biointerphases       Date:  2011-06       Impact factor: 2.456

Review 3.  Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors.

Authors:  Marie Pospíšilová; Gabriela Kuncová; Josef Trögl
Journal:  Sensors (Basel)       Date:  2015-09-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.