Literature DB >> 16935580

Agreement and repeatability for standard automated perimetry and confocal scanning laser ophthalmoscopy in the diagnostic innovations in glaucoma study.

Diana Ng1, Linda M Zangwill, Lyne Racette, Christopher Bowd, John P Pascual, Rupert R A Bourne, Catherine Boden, Robert N Weinreb, Pamela A Sample.   

Abstract

PURPOSE: To assess agreement between structural and functional testing in classifying eyes as normal or abnormal and their repeatability on two consecutive visits by means of standard automated perimetry (SAP) and confocal scanning laser ophthalmoscopy.
DESIGN: Analysis of selected data obtained from a prospective longitudinal observational cohort study, the Diagnostic Innovations in Glaucoma Study.
METHODS: One hundred fifty-one participants with a SAP and a Heidelberg Retina Tomograph (HRT) test within a three-month window at two visits within 15 months were included. Eyes were classified by SAP and HRT at each visit. Agreement and repeatability were assessed by kappa statistics.
RESULTS: At visit 1, 33 (22%) of 151 eyes had only SAP defects, 11 (7%) eyes had only HRT defects, and 35 (23%) eyes had both SAP and HRT defects. Seventy-two eyes (48%) were classified as normal by both tests. Similar results were obtained for visit 2. The agreement between SAP and HRT in classifying eyes was 70% (kappa = 0.393) at visit one and 68% (kappa = 0.363) at visit 2. Repeatability of classification by SAP alone, HRT alone, and both SAP and HRT between visits 1 and 2 was 84% (kappa = 0.693), 89% (kappa = 0.752), and 90% (kappa = 0.723), respectively.
CONCLUSIONS: Agreement between SAP and HRT was only fair at both visits. Repeatability across visits was substantial for SAP alone, HRT alone, and for the combination of SAP and HRT. These results suggest that detection of particular features of glaucomatous damage depends on the technique used. Structural and functional tests appear complementary, and both should be used for early detection of glaucoma.

Entities:  

Mesh:

Year:  2006        PMID: 16935580     DOI: 10.1016/j.ajo.2006.04.027

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  Repeatability of in vivo 3D lamina cribrosa microarchitecture using adaptive optics spectral domain optical coherence tomography.

Authors:  Zach Nadler; Bo Wang; Gadi Wollstein; Jessica E Nevins; Hiroshi Ishikawa; Richard Bilonick; Larry Kagemann; Ian A Sigal; R Daniel Ferguson; Ankit Patel; Daniel X Hammer; Joel S Schuman
Journal:  Biomed Opt Express       Date:  2014-03-10       Impact factor: 3.732

Review 2.  Clinical application of ocular imaging.

Authors:  Zach Nadler; Gadi Wollstein; Hiroshi Ishikawa; Joel S Schuman
Journal:  Optom Vis Sci       Date:  2012-05       Impact factor: 1.973

3.  Relationship between pattern electroretinogram, standard automated perimetry, and optic nerve structural assessments.

Authors:  Mitra Sehi; Mariana Pinzon-Plazas; William J Feuer; David S Greenfield
Journal:  J Glaucoma       Date:  2009 Oct-Nov       Impact factor: 2.503

4.  Signal-to-Noise Ratios for Structural and Functional Tests in Glaucoma.

Authors:  Stuart K Gardiner; Brad Fortune; Shaban Demirel
Journal:  Transl Vis Sci Technol       Date:  2013-10-29       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.