Literature DB >> 16934398

Solid phase extraction of lead on octadecyl bonded silica membrane disk modified with Cyanex302 and determination by flame atomic absorption spectrometry.

Manjusha Karve1, Reeta V Rajgor.   

Abstract

A simple, reliable and rapid method for preconcentration and determination of lead using octadecyl bonded silica membrane disk impregnated with Cyanex302 and flame atomic absorption spectrometry is presented. The influence of aqueous phase pH, type of eluent, flow rates of sample solution and eluent, volume of eluent and amount of extractant has been investigated. The break through volume is greater than 4.0 dm(3) with an enrichment factor of more than 400 and a detection limit of 1.0microg dm(-3). The method developed for determination of lead is good as six replicate determinations using 100cm(3) solution containing lead in the range 1-4900microg provides a relative standard deviation (R.S.D.) of 0.4%. The selectivity of the proposed method was confirmed from the interference studies. The developed procedure was successfully applied for the determination of lead in spiked sea water, USGS standard soil sample, sludge and industrial effluents, medicinal formulation, plant, some food products and wine.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16934398     DOI: 10.1016/j.jhazmat.2006.07.013

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

1.  Quantification of ultra-trace amounts of copper by using off-line solid phase extraction-flame atomic absorption spectrometric determination through the octadecyl silica-bonded phase membrane (OSPM) C18 disks impregnated with 2,2'-[ethane-1,2-diylbis(thio)]dianiline.

Authors:  Majid Mohammadhosseini; Esmaeil Soliemani
Journal:  Environ Monit Assess       Date:  2014-07       Impact factor: 2.513

2.  Synthesis, spectral assignment and application of a recently synthesized macrocyclic ionophore to simultaneous pre-concentration and determination of ultra traces of copper and lead by solid phase extraction-flame atomic absorption spectrometry.

Authors:  Majid Mohammadhosseini; Esmaeil Soliemani
Journal:  Environ Monit Assess       Date:  2013-07-10       Impact factor: 2.513

3.  Selective preconcentration separation of Hg(ii) and Cd(ii) from water, fish muscles, and cucumber samples using recycled aluminum adsorbents.

Authors:  A B Abdallah; Ehab A Abdelrahman; Adel M Youins; Wesam A Ibrahim; Magdi E Khalifa
Journal:  RSC Adv       Date:  2022-03-10       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.