Literature DB >> 16931256

ReSTOR intraocular lens implantation in cataract surgery: quality of vision.

Patrick J T Chiam1, Jin H Chan, Rajesh K Aggarwal, Sam Kasaby.   

Abstract

PURPOSE: To compare the visual outcome and subjective visual symptoms in patients who had implantation of the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories) with those in patients who received the AcrySof SA60AT monofocal IOL (Alcon Laboratories) in cataract surgery.
SETTING: Southend Hospital, Essex, United Kingdom.
METHODS: Eighty eyes of 40 patients received the ReSTOR multifocal IOL after cataract extraction. They were closely paired in age, sex, and ocular findings with patients who had monofocal IOL implantation during the same period. The distance and near visual acuities were compared, and patient satisfaction with their vision, visual symptoms, and spectacle dependence was assessed using a standardized questionnaire.
RESULTS: There was no significant difference in the mean uncorrected and best corrected distance visual acuities between the groups. An uncorrected distance visual acuity of 20/30 or better was achieved in 93.8% eyes in the multifocal group and 82.5% in the monofocal group and of 20/20 or better in 57.5% and 40.0%, respectively (P = .18). Uncorrected near visual acuity was 20/30 or better in 75.0% of eyes in the multifocal group and 3.8% in the monofocal group. Reading glasses were required by 2.5% in the multifocal group and by 92.5% in the monofocal group. Satisfactory uncorrected intermediate distance vision was achieved in 75.0% of eyes in the multifocal group and 87.5% in the monofocal group (P = .089); 85.0% of patients in the multifocal group and 7.5% in the monofocal group never had to wear glasses. Moderate glare was reported by 21.3% in the multifocal group and 7.5% in the monofocal group (P = .008); no patient reported severe glare. In the multifocal group, severe halos and moderate halos occurred in 3.8% [corrected] of eyes and 16.3% [corrected] of eyes, respectively.
CONCLUSIONS: The AcrySof ReSTOR IOL provided predictably good uncorrected distance and uncorrected near acuities. Spectacle independence was significantly higher with this multifocal IOL, which outweighed the photic symptoms it caused.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16931256     DOI: 10.1016/j.jcrs.2006.04.015

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  22 in total

Review 1.  [Apodized diffractive optic. New concept in multifocal lens technology].

Authors:  T Kohnen; V Derhartunian
Journal:  Ophthalmologe       Date:  2007-10       Impact factor: 1.059

2.  [Bioptics with multifocal lenses and Lasek].

Authors:  A Liekfeld; L Friederici; P Rieck
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

3.  All-distance visual acuity in eyes with a nontinted or a yellow-tinted diffractive multifocal intraocular lens.

Authors:  Ken Hayashi; Miki Masumoto; Hideyuki Hayashi
Journal:  Jpn J Ophthalmol       Date:  2009-03-31       Impact factor: 2.447

4.  Internal spherical aberration by ray tracing-type aberrometry in multifocal pseudophakic eyes.

Authors:  I Jun; Y J Choi; E K Kim; K Y Seo; T-I Kim
Journal:  Eye (Lond)       Date:  2012-06-29       Impact factor: 3.775

5.  Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation.

Authors:  G Prakash; D R Prakash; A Agarwal; D A Kumar; A Agarwal; S Jacob
Journal:  Eye (Lond)       Date:  2011-06-17       Impact factor: 3.775

6.  Initial results of trifocal diffractive IOL implantation.

Authors:  Anna Voskresenskaya; Nadezhda Pozdeyeva; Nicolay Pashtaev; Yevgeniy Batkov; Valeriy Treushnicov; Valentin Cherednik
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-06-05       Impact factor: 3.117

7.  Contrast visual acuity after multifocal intraocular lens implantation: aspheric versus spherical design.

Authors:  Jun-Hua Li; Yi-Fan Feng; Yun-E Zhao; Yin-Ying Zhao; Lei Lin
Journal:  Int J Ophthalmol       Date:  2014-02-18       Impact factor: 1.779

8.  [A new toric diffractive multifocal lens for refractive surgery].

Authors:  A Liekfeld; N Torun; L Friederici
Journal:  Ophthalmologe       Date:  2010-03       Impact factor: 1.059

9.  Measuring benefits and patients' satisfaction when glasses are not needed after cataract and presbyopia surgery: scoring and psychometric validation of the Freedom from Glasses Value Scale (FGVS).

Authors:  Gilles Berdeaux; Juliette Meunier; Benoit Arnould; Muriel Viala-Danten
Journal:  BMC Ophthalmol       Date:  2010-05-24       Impact factor: 2.209

10.  Spectacle independence and subjective satisfaction of ReSTOR multifocal intraocular lens after cataract or presbyopia surgery in two European countries.

Authors:  Béatrice Cochener; Luis Fernández-Vega; Jose F Alfonso; Frédérique Maurel; Juliette Meunier; Gilles Berdeaux
Journal:  Clin Ophthalmol       Date:  2010-03-04
View more