Literature DB >> 16929437

Safe zone for the superior gluteal nerve in the transgluteal approach to the dysplastic hip: intraoperative evaluation using a nerve stimulator.

Masahiko Ikeuchi1, Teruhiko Kawakami, Norio Yamanaka, Yusuke Okanoue, Toshikazu Tani.   

Abstract

BACKGROUND: The superior gluteal nerve can be damaged during the transgluteal approach to the hip in total hip arthroplasty.
METHODS: We studied 30 patients with hip dysplasia who underwent total hip arthroplasty through the transgluteal approach. The course of the inferior branch of the superior gluteal nerve was identified using a nerve stimulator. The distance between the nerve and the tip of the greater trochanter was measured.
RESULTS: The mean distance was 37 (25-45) mm at the anterior third, 40 (30-50) mm at the middle third, and 44 (35-55) mm at the posterior third of the gluteus medius. The distance was influenced by the severity of hip dysplasia and decreased as the degree of hip dysplasia became more severe.
INTERPRETATION: A 3-cm safe zone is appropriate in most dysplastic hips. In severely dysplastic hips, however, the superior gluteal nerve occasionally coursed within 3 cm of the tip of the greater trochanter. In such hips, a nerve stimulator can be used to identify the nerve.

Entities:  

Mesh:

Year:  2006        PMID: 16929437     DOI: 10.1080/17453670610012674

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  6 in total

Review 1.  [Revision arthroplasty of the hip : Direct anterior approach].

Authors:  M Krismer; M Nogler
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

2.  Anatomical and CT angiographic study of superior gluteal neurovascular pedicle: implications for hip surgery.

Authors:  Carla Stecco; Veronica Macchi; Luca Baggio; Andrea Porzionato; A Berizzi; Roberto Aldegheri; Raffaele De Caro
Journal:  Surg Radiol Anat       Date:  2012-09-16       Impact factor: 1.246

3.  [Modified mini-Hardinge access for hip prosthesis implantation in the supine position].

Authors:  F Mazoochian; F Schmidutz; A Fottner; V Jansson
Journal:  Oper Orthop Traumatol       Date:  2014-04-03       Impact factor: 1.154

Review 4.  [Nerve lesions after minimally invasive total hip arthroplasty].

Authors:  B M Holzapfel; F Heinen; D E Holzapfel; K Reiners; U Nöth; M Rudert
Journal:  Orthopade       Date:  2012-05       Impact factor: 1.087

5.  Infectiological, functional, and radiographic outcome after revision for prosthetic hip infection according to a strict algorithm.

Authors:  F Harald R De Man; Parham Sendi; Werner Zimmerli; Thomas B Maurer; Peter E Ochsner; Thomas Ilchmann
Journal:  Acta Orthop       Date:  2010-12-29       Impact factor: 3.717

6.  Do Acetabular Buttress Augment Pose Risk to the Superior Gluteal Nerve? A Cadaveric Study.

Authors:  Austin A Cole; Parker R Zimmerman; Michael S Sridhar
Journal:  Arthroplast Today       Date:  2020-12-21