Literature DB >> 16929200

Acellular dermal composite allografts for reconstruction of the radial forearm donor site.

Norman M Rowe1, Luc Morris, Mark D Delacure.   

Abstract

PURPOSE: Since its description in the 1970s, the radial forearm free flap has earned a clearly defined role in the armamentarium of reconstructive head and neck surgery. Three decades later, the donor site remains an intrinsic drawback primarily due to its esthetic impact, although functional morbidity is significant in a minority. These points do not outweigh significant advantages but are occasionally reasons for the choice of alternative flaps. Modifications evolved in an effort to improve these undesirable features include primary closure, rotation-advancement, proximal paddle placement, full-thickness skin graft (FTSG) and suprafascial dissection. We describe a novel technique of engineering a composite graft of cadaveric acellular dermal matrix and autologous split-thickness skin graft (STSG) for a better donor-site closure.
METHODS: From December 1995 to August 2003, 23 patients underwent radial forearm reconstruction of head and neck defects. Control patients (Group I; n = 5) had donor sites closed by conventional STSG technique (0.014-0.016 inch). In 18 patients (Group II), the donor site was closed with a composite technique (dermal allograft, 0.020-0.030 inch, and an ultrathin STSG, 0.0080 inch). Both groups of patients were retrospectively studied for comparative defects. Contralateral upper extremities also served as controls. All patients underwent a standardized functional examination of the donor and contralateral extremities, as well as an outcome questionnaire. All extremities were photographed for visual comparison by the author.
RESULTS: Three of the 5 group I patients were available for follow-up, which averaged 64 months (60-72 months). Thirty-three percent had a decrease in functional parameters and 67% complained of paresthesia. Patient satisfaction was 3.5/5. Six of the 18 patients were excluded from Group II due to insufficient follow-up or inability to follow. Follow-up averaged 8 months (1-24 months). Functional parameters in all patients were comparable to the contralateral extremity, except in 1 patient. In this case, a 0.030-inch allograft was used which never revascularized, inhibiting wrist motion. Other patients exhibited excellent range of motion of the wrist and fingers. This was the only patient in this group that exhibited paresthesia of the donor site. Patient satisfaction was 4.6/5. Esthetic results were extremely gratifying as judged by the author. Esthetic results were better than those observed in Group I.
CONCLUSIONS/SIGNIFICANCE: Composite grafting with acellular dermal matrix and STSG provides a comparable (trending to superior) result with traditional STSG for the treatment of radial forearm graft donor sites. Even if functionally equivalent, it is esthetically superior and therefore a technique warranting further investigation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16929200     DOI: 10.1097/01.sap.0000221622.41450.60

Source DB:  PubMed          Journal:  Ann Plast Surg        ISSN: 0148-7043            Impact factor:   1.539


  8 in total

1.  The use of skin substitutes in the treatment of the hand and upper extremity.

Authors:  John T Capo; Kyle P Kokko; Marco Rizzo; Julie E Adams; Ben Shamian; Brenon Abernathie; Eitan Melamed
Journal:  Hand (N Y)       Date:  2014-06

2.  Repair of symptomatic forearm hernias using acellular dermal matrix--two case reports.

Authors:  Jeffrey H Kozlow; Richard J Beil; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2010-10-20       Impact factor: 2.230

Review 3.  Dermal skin substitutes for upper limb reconstruction: current status, indications, and contraindications.

Authors:  Shady A Rehim; Maneesh Singhal; Kevin C Chung
Journal:  Hand Clin       Date:  2014-05       Impact factor: 1.907

4.  Reduction of donor site morbidity of free radial forearm flaps: what level of evidence is available?

Authors:  Denys J Loeffelbein; Sammy Al-Benna; Lars Steinsträßer; Robin M Satanovskij; Nils H Rohleder; Thomas Mücke; Klaus-Dietrich Wolff; Marco R Kesting
Journal:  Eplasty       Date:  2012-02-03

5.  Double-layered collagen graft to the radial forearm free flap donor sites without skin graft.

Authors:  Tae-Jun Park; Hong-Joon Kim; Kang-Min Ahn
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-12-01

6.  Revision surgery with dermal regeneration template and vacuum sealing drainage for reconstruction of complex wounds following necrosis of reattached avulsed skins in a degloving injury: A case report.

Authors:  Zhenmu Lv; Lili Yu; Lei Fu; Qiusheng Wang; Rui Jia; Wenyuan Ding; Yong Shen
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

7.  The use of dermal regeneration template for treatment of complex wound with bone/tendon exposed at the forearm and hand, a prospective cohort study.

Authors:  Zhenmu Lv; Lili Yu; Qiusheng Wang; Rui Jia; Wenyuan Ding; Yong Shen
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

Review 8.  Skin grafting treatment of adolescent lower limb avulsion injury.

Authors:  Liu Yang; Jiachao Guo; Jinpeng He; Jingfan Shao
Journal:  Front Surg       Date:  2022-09-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.