Literature DB >> 16928163

Fate of endoleaks detected by CT angiography and missed by color duplex ultrasound in endovascular grafts for abdominal aortic aneurysms.

Ali F AbuRahma1.   

Abstract

PURPOSE: To analyze the clinical implications of endoleaks documented by computed tomographic angiography (CTA) and missed by color duplex ultrasound (CDU).
METHODS: During a recent 5-year period, 232 patients underwent endovascular aortic reconstruction (EVAR) and were followed according to a protocol that included CTA and CDU at 1 month and every 6 months thereafter. CTA was the gold standard for determining the presence of endoleaks. The size of the AAA sac at the latest postoperative follow-up was compared to the preoperative size and correlated to the type of endoleak and clinical outcome. This study analyzed only patients with endoleak documented by CTA and CDU and specifically analyzed the outcome of patients with false negative CDU studies for endoleaks.
RESULTS: Thirty-nine endoleaks were documented in 35 (15%) of 232 patients using CTA. Four patients had both early and late endoleaks. The mean follow-up was 25 months (range 1-64). CDU was more helpful in detecting type I endoleaks than type II endoleaks (89% versus 58%, p<0.05). There were 18 (46%) type I endoleaks (12 early, 6 late) detected by CTA; 16 (89%) of these were detected by CDU (2 late endoleaks missed). Nineteen (49%) type II endoleaks (16 early, 3 late) were diagnosed using CTA, 11 (58%) of which were detected by CDU (6 early and 2 late missed). Of the 2 (5%) early type IV endoleaks found on CTA, 1 (50%) was missed by CDU. Overall, CDU failed to identify endoleak in 11 (28%) of 39 endoleaks [2 late type I, 8 type II (6 early, 2 late), and 1 early type IV]. Consequences to treatment occurred in 2 (20%): 1 type I endoleak required treatment and 1 type II endoleak would have missed treatment.
CONCLUSION: CDU has a lower sensitivity in detecting endoleak, particularly type II; therefore, EVAR surveillance should not be based solely on CDU. Although a significant number of type II endoleaks resolved spontaneously, intervention can be offered for type II endoleaks if associated with an increasing sac size.

Entities:  

Mesh:

Year:  2006        PMID: 16928163     DOI: 10.1583/06-1874R.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  3 in total

1.  Management of Immediate Post-Endovascular Aortic Aneurysm Repair Type Ia Endoleaks and Late Outcomes.

Authors:  Ali F AbuRahma; Stephen M Hass; Zachary T AbuRahma; Michael Yacoub; Albeir Y Mousa; Shadi Abu-Halimah; L Scott Dean; Patrick A Stone
Journal:  J Am Coll Surg       Date:  2016-12-23       Impact factor: 6.113

Review 2.  Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis.

Authors:  Georgios I Karaolanis; Constantine N Antonopoulos; Efstratios Georgakarakos; Georgios D Lianos; Michail Mitsis; Georgios K Glantzounis; Athanasios Giannoukas; George Kouvelos
Journal:  J Clin Med       Date:  2022-06-23       Impact factor: 4.964

3.  Increased fluorodeoxyglucose uptake following endovascular abdominal aortic aneurysm repair: a predictor of endoleak?

Authors:  Kosmas I Paraskevas; Alexandros A Tzovaras; Vassilios Stathopoulos; Fotini Gentimi; Dimitri P Mikhailidis
Journal:  Open Cardiovasc Med J       Date:  2010-04-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.