Literature DB >> 16925463

ECG body surface mapping (BSM) in type 1 diabetic patients.

D Zdárská1, P Pelísková, J Charvát, J Slavícek, M Mlcek, E Medová, O Kittnar.   

Abstract

Diabetes mellitus is a risk factor of cardiovascular diseases. ECG of patients with diabetes mellitus type 1 (DM 1) shows tachycardia (block of parasympathetic innervation) and abnormal repolarization (increased QT interval and QT dispersion (QTd)) indicating a risk of ventricular tachycardia and sudden death in young people with DM 1. The aim of the present report was to measure 145 parameters of the heart electric field in 22 patients (14 men, 8 women) with DM 1 without complications (mean age 32.8+/-11.4 years) and in 22 controls (11 men, 11 women, mean age 30.1+/-3.4 years). The duration of diabetes was 13.9+/-7.8 years. The parameters were registered by the diagnostic system Cardiag 112.2 and statistically evaluated by the Student and Mann-Whitney test. Tachycardia (86.3+/-2.7 beats.min(-1)), shortening of both QRS (79.9+/-1.6 ms) and QT (349.0+/-5.9 ms) and increased QT dispersion (115+/-36 ms) were observed in DM 1 when compared with the controls (75.0+/-2.1 beats. min.(-1), QRS 89.9+/-2.7 ms, QT 374.0+/-4.4 ms, QTd 34.0+/-12.0 ms, p<0.01). The QTc was 415.2+/-4.1 ms in DM 1 and 401.4+/-6.6 ms in controls (NS). Other significant findings in DM 1 were: higher maximum of depolarization isopotential maps (DIPMmax) in the initial phase of QRS and less positive in the terminal phase, more negative minimum (DIPMmin) during QRS similarly as the minimum in depolarization isointegral maps (DIIMmin) and the minimum in isointegral map of the Q wave (Q-IIMmin), lower maximum in repolarization isopotential maps (RIPMmax) and less negative minimum (RIPMmin), more negative amplitude of Q wave (Q-IPMAM) and more pronounced spread of depolarization (activation time). Our results confirmed a decreased parasympathetic to sympathetic tone ratio (tachycardia, shortening of the activation time) and revealed different depolarization and repolarization patterns in DM 1. The differences in heart electric field parameters measured by the BSPM method in DM 1 and in the controls indicate the importance of ECG examination of diabetic patients type 1 in the prevention of cardiovascular diseases.

Entities:  

Mesh:

Year:  2006        PMID: 16925463

Source DB:  PubMed          Journal:  Physiol Res        ISSN: 0862-8408            Impact factor:   1.881


  5 in total

Review 1.  Mechanisms underlying the impaired contractility of diabetic cardiomyopathy.

Authors:  Marie-Louise Ward; David J Crossman
Journal:  World J Cardiol       Date:  2014-07-26

Review 2.  Electrocardiological features in obesity: the benefits of body surface potential mapping.

Authors:  Gábor Simonyi
Journal:  Cardiorenal Med       Date:  2014-07-05       Impact factor: 2.041

3.  QT interval dispersion in the patients with central serous chorioretinopathy.

Authors:  Necati Dagli; Burak Turgut; Rumeysa Tanyildizi; Sabiha Kobat; Mehmet Ali Kobat; Orhan Dogdu
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

Review 4.  The ECG vertigo in diabetes and cardiac autonomic neuropathy.

Authors:  Christina Voulgari; Nicholas Tentolouris; Christodoulos Stefanadis
Journal:  Exp Diabetes Res       Date:  2011-05-29

5.  Clinical Significance of Statistical Differences.

Authors:  Luiz Maurino Abreu
Journal:  Arq Bras Cardiol       Date:  2020-02       Impact factor: 2.000

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.