Literature DB >> 16922757

The anatomical position of three extraglottic airway devices in patients with clear airways.

A van Zundert1, J Brimacombe, R Kamphuis, M Haanschoten.   

Abstract

We tested the hypothesis that, in patients with clear airways, the anatomical position of three single-use extraglottic airway devices is similar. The airways studied were: the laryngeal mask airway unique (LMA-U), the Softseal laryngeal mask airway (SS-LM) and the Cobra perilaryngeal airway (Cobra-PLA). Three hundred spontaneously breathing patients were randomly allocated to have their airway managed using one of these three supraglottic airway devices. A rigid endoscope was passed down the airway tube and the following anatomical assessments were made: position of the epiglottis; position of the glottis; and position of the cuff. The epiglottis was more frequently visible with the LMA-U than with the SS-LM (76 vs 57%, p = 0.006) and with the LMA-U than with the Cobra-PLA (76 vs 46%, p < 0.0001). The epiglottis was in contact with the mask aperture bars in 25% of patients, and in 34% of these, the epiglottis was seen to be herniated through the aperture bars. Herniation of the epiglottis through the mask aperture bars occurred more frequently with the Cobra-PLA than the LMA-U (8 vs 3%, p = 0.008). The vocal cords and arytenoids were more frequently visible with the LMA-U and SS-LM than with the Cobra-PLA (both p < 0.006). Herniation of the arytenoids through the mask aperture bars was more frequently seen with the Cobra-PLA than with the LMA-U (8 vs 0%, p = 0.004). The position of the cuff was optimal for the LMA-U and SS-LM in 90% and 93% of patients, respectively. The cuff was more frequently in the midline with the LMA-U than with the SS-LM (p = 0.002). We conclude that the anatomical position of the LMA-U and SS-LMA is superior to that of the Cobra-PLA in patients with clear airways. The mask aperture bars probably have no anatomical utility and predispose to herniation of the pharyngeal structures.

Entities:  

Mesh:

Year:  2006        PMID: 16922757     DOI: 10.1111/j.1365-2044.2006.04745.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  7 in total

1.  The effect of cuff pressure on postoperative sore throat after Cobra perilaryngeal airway.

Authors:  Han Bum Joe; Dae Hee Kim; Yun Jeong Chae; Jong Yeop Kim; Min Kang; Kwan Sik Park
Journal:  J Anesth       Date:  2011-11-30       Impact factor: 2.078

2.  Comparison of the ProSeal laryngeal mask airway with the I-Gel™ in the different head-and-neck positions in anaesthetised paralysed children: A randomised controlled trial.

Authors:  Gargi Banerjee; Divya Jain; Indu Bala; Komal Gandhi; Ram Samujh
Journal:  Indian J Anaesth       Date:  2018-02

3.  Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.

Authors:  Yuan Tan; Guangyou Duan; Qin Chen; Feng Chen; Hong Li
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

4.  Comparison of Two Supraglottic Airway Devices: I-gel Airway and ProSeal Laryngeal Mask Airway Following Digital Insertion in Nonparalyzed Anesthetized Patients.

Authors:  Ankur Luthra; Rajeev Chauhan; Amit Jain; Ishwar Bhukal; Shalvi Mahajan; Indu Bala
Journal:  Anesth Essays Res       Date:  2019-12-16

5.  Baska Mask is non-inferior to tracheal tube in preventing airway contamination during controlled ventilation in elective nasal surgeries: A randomised controlled trial.

Authors:  H Priya; R Sripriya; M Ravishankar; P Karthikeyan; R Charulatha
Journal:  Indian J Anaesth       Date:  2021-08-25

6.  Comparison of I-gel with proseal LMA in adult patients undergoing elective surgical procedures under general anesthesia without paralysis: A prospective randomized study.

Authors:  Gurudas Kini; Gopalkrishna Mettinadka Devanna; Koteswara Rao Mukkapati; Souvik Chaudhuri; Daniel Thomas
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-04

Review 7.  Extraglottic airway devices: technology update.

Authors:  Bimla Sharma; Chand Sahai; Jayashree Sood
Journal:  Med Devices (Auckl)       Date:  2017-08-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.