Quantitative analysis of neovascularization of different PTFE-implants.

M D Menger1, P Walter, F Hammersen, K Messmer.   

Abstract

The process of neovascularization was analyzed in vivo in different expanded polytetrafluoroethylene (e-PTFE) implants which are frequently used in cardio-thoracic and vascular surgery. We have used the model of the hamster dorsal skinfold chamber which allows quantitative analysis of the microcirculation by means of intravital fluorescence microscopy. Pieces of approximately 1 mm2 of the cardiovascular patch (CVP, fibril length: 30 microns; n = 21), surgical membrane (SM, fibril length: 1 micron; n = 16), and soft tissue patch (STP, fibril length: 22 microns; n = 12) were implanted into the skinfold chambers. On day 10 after implantation, the functional density of newly formed microvessels was significantly (P less than 0.05) higher in CVP (145.0 +/- 10.9 cm-1) as compared to SM (688 +/- 13.9 cm-1) and STP (86.9 +/- 21.2 cm-1). In addition, CVP revealed a larger zone of neovascularization (311.6 +/- 19.4 microns) and the tightest integration (dynamic breaking strength: 17.9 +/- 3.0 cN/mm2) into the perigraft tissue, while SM demonstrated only few microvessels and no integration (6.0 +/- 1.9 cN/mm2) into the perigraft. None of the three different PTFE-implants revealed transmural ingrowth of capillaries. The internodal distance of PTFE implants seems to be the most important factor for neovascularization. Surgical membrane used for the replacement of passive biological membranes demonstrated, as is its purpose, little neovascularization and no integration into the perigraft tissue.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1692226     DOI: 10.1016/1010-7940(90)90003-i

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

1.  Percutaneous window chamber method for chronic intravital microscopy of sensor-tissue interactions.

Authors:  Heidi E Koschwanez; Bruce Klitzman; W Monty Reichert
Journal:  J Diabetes Sci Technol       Date:  2008-11

2.  Intravital microscopy evaluation of angiogenesis and its effects on glucose sensor performance.

Authors:  H E Koschwanez; W M Reichert; B Klitzman
Journal:  J Biomed Mater Res A       Date:  2010-06-15       Impact factor: 4.396

3.  Spiny lobster sounds can be detectable over kilometres underwater.

Authors:  Youenn Jézéquel; Laurent Chauvaud; Julien Bonnel
Journal:  Sci Rep       Date:  2020-05-21       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.