| Literature DB >> 16920318 |
Li Ding1, Li Li, Pengcheng Ma.
Abstract
A liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method for the determination of azelnidipine in human plasma was established. Nicardipine was used as the internal standard (IS). After adjustment to a basic pH with sodium hydroxide solution (0.1 M), plasma samples were extracted with cyclohexane-diethyl ether (1:1, v/v) and separated on a C(18) column with a mobile phase of 20 mM ammonium acetate solution-methanol-formic acid (25:75:0.5, v/v). The electrospray ionization was employed in a single quadrupole mass spectrometer for the determination. The method was linear over the concentration range of 0.05-40 ng/ml. The lower limit of quantification (LLOQ) was 0.05 ng/ml. The intra- and inter-run standard deviations were less than 9.5% and 11.0%, respectively. The method was successfully applied to study the pharmacokinetics of azelnidipine in healthy Chinese volunteers.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16920318 DOI: 10.1016/j.jpba.2006.07.011
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935