Literature DB >> 16919652

Coupling of sequential injection analysis and capillary electrophoresis - Laser-induced fluorescence via a valve interface for on-line derivatization and analysis of amino acids and peptides.

Constantinos K Zacharis1, F W Alexander Tempels, Georgios A Theodoridis, Anastasios N Voulgaropoulos, Willy J M Underberg, Govert W Somsen, Gerhardus J de Jong.   

Abstract

The on-line coupling of sequential injection analysis (SIA) and capillary electrophoresis (CE) via an in-line injection valve is presented. The SIA system is used for automated derivatization of amino acids and peptides. Dichlorotriazinylaminofluorescein serves as the derivatization agent, thus enabling sensitive laser-induced fluorescence detection of the derivatized analytes. The SIA procedure includes the following steps: (a) introduction of reagent and sample zones in a holding coil, (b) sample and reagent mixing in a reaction coil, (c) stop-flow step for increase of the reaction time, and (d) delivery of derivatized sample into the loop of the micro-valve interface. A small portion of the analyte zone is introduced electrokinetically in the separation capillary via the valve interface and CE analysis is performed. Factors affecting the CE separation, such as pH, the borate and sodium dodecyl sulphate concentration of the background electrolyte have been optimized. The derivatization conditions have been studied to obtain a high reaction yield in a relative short time. The transfer of a part of the reaction plug into the loop of the valve interface has been optimized. Using des-Tyr(1)-[Met]-enkephalinamide as test compound, it is demonstrated that after automated derivatization, on-line electrophoretic analysis could be achieved. Glycine has been selected as the internal standard in order to correct for variations in reaction time and filling of the injection loop. For the enkephalin, good reproducibility (RSD<4.5% calculated by the ratio of the peak areas) and linearity (0.5-5 microg mL(-1), R(2)>or=0.994) are obtained with a detection limit of 30 ng mL(-1) (S/N=3).

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16919652     DOI: 10.1016/j.chroma.2006.07.076

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Coaxial flow system for chemical cytometry.

Authors:  Paul J Marc; Christopher E Sims; Nancy L Allbritton
Journal:  Anal Chem       Date:  2007-11-03       Impact factor: 6.986

Review 2.  Capillary electrophoresis in bioanalysis.

Authors:  Vratislav Kostal; Joseph Katzenmeyer; Edgar A Arriaga
Journal:  Anal Chem       Date:  2008-05-17       Impact factor: 6.986

3.  Microelectrophoresis platform for fast serial analysis of single cells.

Authors:  Dechen Jiang; Christopher E Sims; Nancy L Allbritton
Journal:  Electrophoresis       Date:  2010-08       Impact factor: 3.535

4.  Hemolymph amino acid analysis of individual Drosophila larvae.

Authors:  Sujeewa C Piyankarage; Hrvoje Augustin; Yael Grosjean; David E Featherstone; Scott A Shippy
Journal:  Anal Chem       Date:  2008-01-15       Impact factor: 6.986

Review 5.  Recent developments in CE and CEC of peptides.

Authors:  Václav Kasicka
Journal:  Electrophoresis       Date:  2008-01       Impact factor: 3.535

6.  Determination of phenylenediamines in hair colors derivatizated with 5-(4, 6-dichlorotriazinyl)aminofluorescein via micellar electrokinetic chromatography.

Authors:  Hung-Yu Ko; Yi-Hui Lin; Chi-Jen Shih; Yen-Ling Chen
Journal:  J Food Drug Anal       Date:  2019-03-21       Impact factor: 6.157

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.