Literature DB >> 16919639

Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion.

Peter M Mills1, Steven Morrison, David G Lloyd, Rod S Barrett.   

Abstract

The purpose of this paper was to describe a technique that enables three-dimensional (3D) gait kinematics to be obtained using an electromagnetic tracking system, and to report the intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of kinematic gait data obtained using this technique. Ten able-bodied adults underwent four gait assessments; the same two testers tested each subject independently on two different days. Gait assessments were conducted on a custom-built long-bed treadmill with no metal components between the rollers. Each gait assessment involved familiarisation to treadmill walking, subject anatomical and functional calibration, and a period of steady-state treadmill walking at a self-selected speed. Following data collection, 3D joint kinematics were calculated using the joint coordinate system approach. 3D joint angle waveforms for 10 left and right strides were extracted and temporally normalised for each trial. Intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of the temporally normalised kinematic waveforms were quantified using the coefficient of multiple determination (CMD). CMDs for joint kinematics averaged 0.942 intra-trial, 0.849 intra-day/inter-tester and 0.773 inter-day/intra-tester. In general, sagittal plane kinematics were more repeatable than frontal or transverse plane kinematics, and kinematics at the hip were more repeatable than at the knee or ankle. The level of repeatability of kinematic gait data obtained during treadmill walking using this protocol was equal or superior to that reported previously for overground walking using image-based protocols.

Entities:  

Mesh:

Year:  2006        PMID: 16919639     DOI: 10.1016/j.jbiomech.2006.06.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  11 in total

1.  Knee kinematics following acl reconstruction in females; the effect of vision on performance during a cutting task.

Authors:  Jaynie Bjornaraa; Richard P Di Fabio
Journal:  Int J Sports Phys Ther       Date:  2011-12

2.  Inter-operator reliability and prediction bands of a novel protocol to measure the coordinated movements of shoulder-girdle and humerus in clinical settings.

Authors:  Pietro Garofalo; Andrea Giovanni Cutti; Maria Vittoria Filippi; Stefano Cavazza; Alberto Ferrari; Angelo Cappello; Angelo Davalli
Journal:  Med Biol Eng Comput       Date:  2009-02-17       Impact factor: 2.602

3.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

Review 4.  Gait analysis using wearable sensors.

Authors:  Weijun Tao; Tao Liu; Rencheng Zheng; Hutian Feng
Journal:  Sensors (Basel)       Date:  2012-02-16       Impact factor: 3.576

5.  Lower extremity kinematics in children with and without flexible flatfoot: a comparative study.

Authors:  Yi-Fen Shih; Chao-Yin Chen; Wen-Yin Chen; Hsiu-Chen Lin
Journal:  BMC Musculoskelet Disord       Date:  2012-03-02       Impact factor: 2.362

6.  Reliability and criterion-related validity with a smartphone used in timed-up-and-go test.

Authors:  Alejandro Galán-Mercant; Francisco Javier Barón-López; María T Labajos-Manzanares; Antonio I Cuesta-Vargas
Journal:  Biomed Eng Online       Date:  2014-12-02       Impact factor: 2.819

Review 7.  Behavioral Dynamics in Swimming: The Appropriate Use of Inertial Measurement Units.

Authors:  Brice Guignard; Annie Rouard; Didier Chollet; Ludovic Seifert
Journal:  Front Psychol       Date:  2017-03-14

8.  The use of inertial sensors system for human motion analysis.

Authors:  Antonio I Cuesta-Vargas; Alejandro Galán-Mercant; Jonathan M Williams
Journal:  Phys Ther Rev       Date:  2010-12

9.  Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics.

Authors:  Wolfgang Teufl; Markus Miezal; Bertram Taetz; Michael Fröhlich; Gabriele Bleser
Journal:  Sensors (Basel)       Date:  2018-06-21       Impact factor: 3.576

10.  Correlation between the distance of scapular anterior tilting and the ratio of internal and external rotation angle of shoulder in supine position.

Authors:  In-Cheol Jeon
Journal:  J Phys Ther Sci       Date:  2018-10-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.