Literature DB >> 16919279

Admission cardiotocography versus intermittent auscultation of fetal heart rate: effects on neonatal Apgar score, on the rate of caesarean sections and on the rate of instrumental delivery--a systematic review.

Kleanthi Gourounti1, Jane Sandall.   

Abstract

OBJECTIVE: The aim of this review was to determine whether intrapartum admission cardiotocography (CTG) in women at low obstetric risk can improve neonatal outcome (in terms of Apgar score) and whether it is associated with an increase in the incidence of instrumental delivery and caesarean section. REVIEW
METHODS: The Cochrane Library, Medline (1966-November 2005), Embase (1980-November 2005) and the PubMed were searched for randomized control trials and systematic reviews of randomized control trials. Studies were assessed for quality. Outcomes considered the neonatal Apgar score at 5 min after delivery, caesarean section and instrumental delivery. A meta-analysis of the results of the randomized controlled trials was performed.
RESULTS: The pooled relative risk for having an Apgar score less than 7 points at 5 min after delivery was higher in the admission CTG group (RR 1.35, 95% CI 0.85-2.13) but it was not statistically significant. The pooled relative risks for having a caesarean section-delivery (RR 1.2 95% CI 1.00-1.41) and an instrumental delivery (RR 1.1 95% CI 1.00-1.18) were both higher in the admission CTG group. Both these were statistically significant.
CONCLUSION: Intrapartum admission cardiotocography in women at low obstetric risk increases the risk of caesarean section and instrumental delivery. In addition, there is no evidence for neonatal benefit in terms of Apgar score at 5 min after delivery. A larger sample size would be needed in order to answer this important question.

Entities:  

Mesh:

Year:  2006        PMID: 16919279     DOI: 10.1016/j.ijnurstu.2006.06.002

Source DB:  PubMed          Journal:  Int J Nurs Stud        ISSN: 0020-7489            Impact factor:   5.837


  6 in total

Review 1.  Planned hospital birth versus planned home birth.

Authors:  Ole Olsen; Jette A Clausen
Journal:  Cochrane Database Syst Rev       Date:  2012-09-12

2.  Accuracy of Fetal Biacromial Diameter and Derived Ultrasonographic Parameters to Predict Shoulder Dystocia: A Prospective Observational Study.

Authors:  Marco La Verde; Pasquale De Franciscis; Clelia Torre; Angela Celardo; Giulia Grassini; Rossella Papa; Stefano Cianci; Carlo Capristo; Maddalena Morlando; Gaetano Riemma
Journal:  Int J Environ Res Public Health       Date:  2022-05-09       Impact factor: 4.614

Review 3.  Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing.

Authors:  Declan Devane; Joan G Lalor; Sean Daly; William McGuire; Anna Cuthbert; Valerie Smith
Journal:  Cochrane Database Syst Rev       Date:  2017-01-26

Review 4.  Antenatal and intrapartum interventions for reducing caesarean section, promoting vaginal birth, and reducing fear of childbirth: An overview of systematic reviews.

Authors:  Valerie Smith; Louise Gallagher; Margaret Carroll; Kathleen Hannon; Cecily Begley
Journal:  PLoS One       Date:  2019-10-24       Impact factor: 3.240

5.  Intelligent Structured Intermittent Auscultation (ISIA): evaluation of a decision-making framework for fetal heart monitoring of low-risk women.

Authors:  Robyn M Maude; Joan P Skinner; Maralyn J Foureur
Journal:  BMC Pregnancy Childbirth       Date:  2014-05-31       Impact factor: 3.007

6.  The Development and Psychometric Evaluation of the Electronic Fetal Monitoring Knowledge Scale.

Authors:  Kleanthi Gourounti; Antigoni Sarantaki; Athina Diamanti; Paraskevi Giaxi; Katerina Lykeridou
Journal:  Acta Inform Med       Date:  2020-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.