Literature DB >> 16919021

Soluble RANKL in crevicular fluid of dental implants: a pilot study.

Gabriel Monov1, Georg D Strbac, Monika Baron, Barbara Kandler, Georg Watzek, Reinhard Gruber.   

Abstract

BACKGROUND: Receptor activator of NF-kappaB ligand (RANKL), a member of the tumor necrosis factor superfamily, is a key mediator of osteoclast formation, activation, and survival. Thus, it is reasonable to hypothesize that there might be a functional relationship between RANKL expression and peri-implantitis.
PURPOSE: This pilot study was performed to determine the reference levels for soluble RANKL (sRANKL) in peri-implant crevicular fluid and to correlate them with the clinical parameters associated with inflammatory reactions and bone destruction.
MATERIALS AND METHODS: The clinical parameters probing depth (PD), modified bleeding index (MBI), and modified plaque index (MPI) served as indicators for bone resorption and inflammation. Exclusion criteria for calculations were the detection limit of the immunoassay and the minimum acceptable crevicular volume for measurement. From the 84 collected samples of 16 patients, 30-84 years of age, with a total of 19 implants, 29 met these criteria. The absolute amount of sRANKL within crevicular fluid adsorbed to filter strips was a median of 0.18 femtomol (fmol; range, 0.08-0.53) and 0.26 nM (range, 0.09-1.21) when normalized by volume. PD was 4 mm in median and varied within a range between 2 and 12 mm.
RESULTS: Absolute amounts of sRANKL showed no correlation with the adsorbed volume and the clinical parameters PD, MBI, and MPI. When sRANKL was normalized by volume, no correlation with the clinical parameters PD, MBI, and MPI was observed either. The patients' age was not associated with total sRANKL and the concentration of RANKL within crevicular fluid. Absolute levels of sRANKL and sRANKL concentration did not show any differences based on the sampling sites buccal and lingual, or on the patients' gender. A significant difference in sRANKL concentration was detectable when samples from maxillary implants (0.31 nM median; range, 0.12-1.21) were compared with samples from mandibular implants (0.21 nM median; range, 0.09-0.6) (p=.03). Absolute levels of sRANKL were not different between the maxilla and the mandible.
CONCLUSION: Given the limited sample size, our data provide a basis for future prospective longitudinal studies on the possible relevance of sRANKL as a prognostic marker in peri-implantitis, and for an understanding of the pathophysiologic process of the disease as a prerequisite for the design of treatment strategies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16919021     DOI: 10.1111/j.1708-8208.2006.00012.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  6 in total

1.  Immobilized-OPG-Fc on a titanium surface inhibits RANKL-dependent osteoclast differentiation in vitro.

Authors:  Seicho Makihira; Yuichi Mine; Hiroki Nikawa; Takahiro Shuto; Eduardo Kosaka; Masaru Sugiyama; Ryuji Hosokawa
Journal:  J Mater Sci Mater Med       Date:  2009-10-16       Impact factor: 3.896

Review 2.  Peri-Implant Crevicular Fluid Analysis, Enzymes and Biomarkers: a Systemetic Review.

Authors:  Erhan Dursun; Tolga Fikret Tözüm
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

3.  Increase in receptor activator of nuclear factor κB ligand/osteoprotegerin ratio in peri-implant gingiva exposed to Porphyromonas gingivalis lipopolysaccharide.

Authors:  Takahiro Shuto; Takanori Wachi; Yoshinori Shinohara; Hiroki Nikawa; Seicho Makihira
Journal:  J Dent Sci       Date:  2016-01-06       Impact factor: 2.080

Review 4.  Peri-Implantitis Diagnosis and Prognosis Using Biomarkers in Peri-Implant Crevicular Fluid: A Narrative Review.

Authors:  Hatem Alassy; Praveen Parachuru; Larry Wolff
Journal:  Diagnostics (Basel)       Date:  2019-12-07

5.  Receptor activator of nuclear factor kappa B ligand and osteoprotegerin levels in gingival crevicular fluid.

Authors:  Fatemeh Sarlati; Mandana Sattari; Shilan Razzaghi; Malihe Nasiri
Journal:  Dent Res J (Isfahan)       Date:  2012-11

6.  Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading.

Authors:  Raif Alan; İsmail Marakoğlu; Seyfullah Haliloğlu
Journal:  J Periodontal Implant Sci       Date:  2015-10-26       Impact factor: 2.614

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.