Literature DB >> 16917133

Reduction of gaseous microembolism during aortic valve replacement using a dynamic bubble trap.

M Schönburg1, T Ziegelhoeffer, B Kraus, A Mühling, M Heidt, U Taborski, T Gerriets, M Roth, S Hein, S Urbanek, W P Klövekorn.   

Abstract

Serious postoperative psycho-neurological dysfunction is at least partially attributed to the occurrence of gaseous microbubbles in the arterial line of extracorporeal circulation (ECC). Therefore, we investigated in a prospective randomized double blind study whether the usage of dynamic bubble trap (DBT) will reduce microbubble load of patients undergoing aortic valve replacement. Patients (n = 41) were divided into group I (GI, n = 22) with DBT introduced into the arterial line of ECC and group II (GII, n = 19) with placebo-DBT instead. Doppler ultrasonography was used for detection of microbubbles before and after DBT, and for detection of high intensity transient signals (HITS) within the middle cerebral artery. The recording time during ECC was divided into period 1 (P1, until aortic clamp removal) and period 2 (P2, clamp removal until the end of ECC). A significant reduction of microbubble load was found in GI only (p < 0.0001 for ECC; p < 0.0001 for P1; p < 0.0025 for P2). A significant difference in number of HITS between the groups was observed in P1 only (p < 0.002 left middle cerebral artery, p < 0.005 right middle cerebral artery), since in P2 the trapped air in left chamber can go to the supraaortal vessels without passing ECC. In conclusion the use of DBT cannot substitute careful venting after aortic declamping. Nevertheless, reduction of HITS in the cross-clamped period of ECC justifies the use of DBT in patients undergoing open chamber surgery.

Entities:  

Mesh:

Year:  2006        PMID: 16917133

Source DB:  PubMed          Journal:  Gen Physiol Biophys        ISSN: 0231-5882            Impact factor:   1.512


  2 in total

1.  Neuroprotective effects of dynamic bubble trap use in patients undergoing pulmonary endarterectomy: a two-arm randomized controlled trial.

Authors:  Stefan Guth; Martin Juenemann; Jasmin El Shazly; Tibo Gerriets; Juergen Hennig; Marius Butz; Sabrina Kastaun; Christoph B Wiedenroth; Markus Schoenburg; Marc Wollenschlaeger; Georg Bachmann
Journal:  J Thorac Dis       Date:  2021-10       Impact factor: 2.895

2.  Impact of bubble size in a rat model of cerebral air microembolization.

Authors:  Martin Juenemann; Mesut Yeniguen; Nadine Schleicher; Johannes Blumenstein; Max Nedelmann; Marlene Tschernatsch; Georg Bachmann; Manfred Kaps; Petr Urbanek; Markus Schoenburg; Tibo Gerriets
Journal:  J Cardiothorac Surg       Date:  2013-10-18       Impact factor: 1.637

  2 in total