Literature DB >> 16916227

Effect of curing method and storage condition on fluoride ion release from a fluoride-releasing resin cement.

Akira Yoda1, Toru Nikaido, Masaomi Ikeda, Hidekazu Sonoda, Richard M Foxton, Junji Tagami.   

Abstract

The purpose of this study was to evaluate fluoride ion release from a resin-modified glass ionomer cement (Fuji IILC improved, FLC) and a fluoridated resin cement (Panavia F, PF) following different curing methods and storage conditions. The specimens, which were either light-cured (LC) or chemical-cured (CC), were stored in either distilled water (DW) or demineralizing solution (DS; pH 4.5) for 1, 3, 7, 15, 30, 60, and 90 days. Fluoride ion release was measured using a fluoride ion-specific electrode. Data (n = 5) were statistically analyzed using one- and three-way ANOVA (p = 0.05). A "burst effect" was observed in the first week from both materials. However, fluoride ion release from FLC was seven times higher than that from PF. Storage in demineralizing solution accelerated the amount of fluoride release from both materials. In addition, LC yielded a lower amount of fluoride ion release from both materials, as compared to CC. It was concluded that both curing mode and storage medium influenced the amount of fluoride release from the tested materials.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16916227     DOI: 10.4012/dmj.25.261

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Resin-modified glass-ionomer setting reaction competition.

Authors:  D W Berzins; S Abey; M C Costache; C A Wilkie; H W Roberts
Journal:  J Dent Res       Date:  2010-01       Impact factor: 6.116

Review 2.  Factors influencing fluoride release in atraumatic restorative treatment (ART) materials: A review.

Authors:  P Divya Kumari; Shahnawaz Khijmatgar; Avidyuti Chowdhury; Edward Lynch; Chitta R Chowdhury
Journal:  J Oral Biol Craniofac Res       Date:  2019-06-27

3.  Efficacy of fluoride varnishes for preventing enamel demineralization after interproximal enamel reduction. Qualitative and quantitative evaluation.

Authors:  Ascensión Vicente; Antonio José Ortiz Ruiz; Belén Manuela González Paz; José García López; Luis-Alberto Bravo-González
Journal:  PLoS One       Date:  2017-04-21       Impact factor: 3.240

4.  Fluoride Release from Glass Ionomer with Nano Filled Coat and Varnish.

Authors:  Valentina Brzović-Rajić; Ivana Miletić; Sevil Gurgan; Kristina Peroš; Željko Verzak; Ana Ivanišević-Malčić
Journal:  Acta Stomatol Croat       Date:  2018-12

5.  Antibacterial activity of self-adhesive resin cements against Streptococcus mutans at different time intervals.

Authors:  Amir-Ahmad Ajami; Sahand Rikhtegaran; Mahmoud Bahari; Sayeh Hamadanchi
Journal:  Iran J Microbiol       Date:  2019-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.