Literature DB >> 16915566

Surface plasmon resonance-enabled mass spectrometry arrays.

Dobrin Nedelkov1, Kemmons A Tubbs, Randall W Nelson.   

Abstract

Biosensors that utilize surface plasmon resonance (SPR) as a method of detection of protein interactions can be used for selective separation of proteins prior to MS analysis. The combination of SPR and MS results in a unique multiplexed detection technology capable of both quantitative and qualitative protein analysis. To further the development of a high-throughput SPR-MS approach, the possibility of arraying binding ligands on SPR chips for affinity capture of proteins and their MS analysis was explored. Antibodies to beta-2-microglobulin, cystatin C, transferrin, and insulin-like growth factors I and II were arrayed on a large number of SPR chips. Human plasma samples were injected over the antibody array chips in an SPR Biosensor, after which on-chip MS analysis was performed to detect the bound proteins. Signals from the targeted proteins were observed for each antibody-derivatized chip, indicating successful antibody immobilization and protein capture. The SPR-MS arrays are robust, highly reproducible, and are capable of high-throughput analysis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16915566     DOI: 10.1002/elps.200600065

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  Pull-down Assay on Streptavidin Beads and Surface Plasmon Resonance Chips for SWATH-MS-based Interactomics.

Authors:  Josef Maryáš; Jakub Faktor; Lenka Čápková; Petr Müller; Petr Skládal; Pavel Bouchal
Journal:  Cancer Genomics Proteomics       Date:  2018 Sep-Oct       Impact factor: 4.069

Review 2.  Nanomedicine--challenge and perspectives.

Authors:  Kristina Riehemann; Stefan W Schneider; Thomas A Luger; Biana Godin; Mauro Ferrari; Harald Fuchs
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

3.  Self-assembled monolayers for MALDI-TOF mass spectrometry for immunoassays of human protein antigens.

Authors:  Steven M Patrie; Milan Mrksich
Journal:  Anal Chem       Date:  2007-06-28       Impact factor: 6.986

4.  Immuno-MALDI-MS in human plasma and on-chip biomarker characterizations at the femtomole level.

Authors:  Alain Rouleau; Marven El Osta; Géraldine Lucchi; Patrick Ducoroy; Wilfrid Boireau
Journal:  Sensors (Basel)       Date:  2012-11-06       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.