Literature DB >> 16914193

The influence of curing times and light curing methods on the polymerization shrinkage stress of a shrinkage-optimized composite with hybrid-type prepolymer fillers.

Anuradha Visvanathan1, Nicoleta Ilie, Reinhard Hickel, Karl-Heinz Kunzelmann.   

Abstract

OBJECTIVES: The aim of the study was to determine the influence of different light curing units (LCU) and regimes on the polymerization shrinkage stress (PSS) and the mechanical properties of a nano-hybrid composite.
MATERIAL AND METHODS: The polymerization shrinkage force (PSF) was measured continuously with compliance compensation for 300s after photo-initiating the composite, Tetric EvoCeram (Ivoclar Vivadent, Schaan, FL, Shade A3) in a Stress-Strain Analyser. Astralis 10, Bluephase and MiniL.E.D LCU with exposure times 10, 20 and 40s were used (C-factor=0.33, n=8 per group). Immediately after the PSF measurements, mechanical properties of the samples were measured at the top and the bottom using a Fischerscope H100C (Helmut Fischer GmbH, Sindelfingen, Germany). Statistical analyses were done using one-way ANOVA (p<0.05) and Tukey post hoc test.
RESULTS: Significant differences in the PSS for 10, 20 and 40s polymerization using Astralis 10 were found. The MiniL.E.D recorded low stress values. Modulus of elasticity is high after curing the composite with Astralis 10 at 10, 20 and 40s and for Bluephase 40s. Low moduli of elasticity were recorded for the MiniL.E.D and for the Bluephase 20 and 10s. The hardness values (HV) followed the same pattern as the modulus of elasticity. The Ramping mode of the MiniL.E.D had prolonged gel point.
CONCLUSIONS: High intensity LCU produce not just high HV but also high shrinkage, making it important to balance both the effects by choosing the appropriate curing time. Soft-start regimes have no paramount benefit in a LED regarding stresses in the clinical situation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16914193     DOI: 10.1016/j.dental.2006.06.019

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  Three-year clinical evaluation of class II posterior composite restorations placed with different techniques and flowable composite linings in endodontically treated teeth.

Authors:  Emel Karaman; Busra Keskin; Ugur Inan
Journal:  Clin Oral Investig       Date:  2016-08-19       Impact factor: 3.573

2.  Effects of light curing modes and ethanol-wet bonding on dentin bonding properties.

Authors:  Mu-Zi Li; Jin-Rui Wang; Hong Liu; Xia Wang; Kang Gan; Xiu-Ju Liu; De-Li Niu; Xiao-Qing Song
Journal:  J Zhejiang Univ Sci B       Date:  2016-09       Impact factor: 3.066

3.  Influence of light-curing mode on the erosion preventive effect of three different resin-based surface sealants.

Authors:  Florian J Wegehaupt; Tobias T Tauböck; Beatrice Sener; Thomas Attin
Journal:  Int J Dent       Date:  2012-09-06

4.  The effect of resin thickness on polymerization characteristics of silorane-based composite resin.

Authors:  Sung-Ae Son; Hyoung-Mee Roh; Bock Hur; Yong-Hoon Kwon; Jeong-Kil Park
Journal:  Restor Dent Endod       Date:  2014-09-05

5.  Clinical performance of a new biomimetic double network material.

Authors:  Christine Dirxen; Uwe Blunck; Saskia Preissner
Journal:  Open Dent J       Date:  2013-09-06

6.  Improved performance of Bis-GMA dental composites reinforced with surface-modified PAN nanofibers.

Authors:  Parisa Amiri; Zahra Talebi; Dariush Semnani; Rouhollah Bagheri; Hossein Fashandi
Journal:  J Mater Sci Mater Med       Date:  2021-06-30       Impact factor: 3.896

  6 in total