In vivo assessment of a rotary left ventricular assist device-induced artificial pulse in the proximal and distal aorta.

Kevin Bourque1, Charles Dague, David Farrar, Kelly Harms, Dan Tamez, William Cohn, Egemeun Tuzun, Victor Poirier, O Howard Frazier.   

Abstract

The increasing clinical use of rotary left ventricular assist devices (LVADs) suggests that chronic attenuation of arterial pulse pressure has no clinically significant detrimental effects. However, it remains possible that modulating LVAD rotor speed to produce an artificial pulse may be of temporary or occasional benefit. We sought to evaluate a pulse produced by a continuous-flow, centrifugal pump in an ovine thoracic and abdominal aorta. Both ventricles of an adult sheep were resected to eliminate all native cardiac contributions to pulsatility, each replaced by a continuous-flow Thoratec HeartMate III blood pump (Burlington, MA, USA). An LVAD-induced pulsatile flow was achieved by sharply alternating the speed of the magnetically levitated rotor of the left pump between 1,500 rpm (artificial diastole) and 5,500 rpm (artificial systole) at a rate of 60 bpm at a "systolic" interval of 30%. A catheter was advanced from the ascending aorta to the iliac bifurcation via the ventricular assist device outflow graft for pressure measurement and data acquisition. The mean LVAD-induced pulse pressures were 34, 29, 27, and 26 mm Hg in the ascending, thoracic, and abdominal aorta, and the iliac bifurcation, respectively. The maximum rate of pressure rise (deltap/deltat) was between 189 and 238 mm Hg/s, approaching that of the native pulse, although the energy equivalent pressure did not exceed the mean arterial pressure. The HeartMate III's relatively stiff speed control, low rotor mass, and robust magnetic rotor suspension result in a responsive system, enabling very rapid speed changes that can be used to simulate physiologic pulse pressure and deltap/deltat.

Entities:  

Mesh:

Year:  2006        PMID: 16911321     DOI: 10.1111/j.1525-1594.2006.00276.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  9 in total

1.  The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies.

Authors:  Carlo R Bartoli; Robert D Dowling
Journal:  Cardiol Clin       Date:  2011-11       Impact factor: 2.213

2.  Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD.

Authors:  Zengsheng Chen; Sofen K Jena; Guruprasad A Giridharan; Michael A Sobieski; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Biol Eng Comput       Date:  2018-11-08       Impact factor: 2.602

3.  Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved?

Authors:  Tohid Pirbodaghi; Siavash Asgari; Chris Cotter; Kevin Bourque
Journal:  Heart Fail Rev       Date:  2014-03       Impact factor: 4.214

4.  Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device.

Authors:  Kazuma Date; Takashi Nishimura; Mamoru Arakawa; Yoshiaki Takewa; Satoru Kishimoto; Akihide Umeki; Masahiko Ando; Toshihide Mizuno; Tomonori Tsukiya; Minoru Ono; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2016-07-19       Impact factor: 1.731

5.  Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system.

Authors:  Kazuma Date; Takashi Nishimura; Yoshiaki Takewa; Satoru Kishimoto; Mamoru Arakawa; Akihide Umeki; Masahiko Ando; Toshihide Mizuno; Tomonori Tsukiya; Minoru Ono; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2016-05-14       Impact factor: 1.731

6.  Comparison of continuous-flow and pulsatile-flow left ventricular assist devices: is there an advantage to pulsatility?

Authors:  Allen Cheng; Christine A Williamitis; Mark S Slaughter
Journal:  Ann Cardiothorac Surg       Date:  2014-11

7.  Continuous-flow total heart replacement device implanted in a 55-year-old man with end-stage heart failure and severe amyloidosis.

Authors:  O H Frazier; William E Cohn
Journal:  Tex Heart Inst J       Date:  2012

Review 8.  Why pulsatility still matters: a review of current knowledge.

Authors:  Davor Barić
Journal:  Croat Med J       Date:  2014-12       Impact factor: 1.351

9.  Insights Into the Low Rate of In-Pump Thrombosis With the HeartMate 3: Does the Artificial Pulse Improve Washout?

Authors:  Peng Fang; Jianjun Du; Andrea Boraschi; Silvia Bozzi; Alberto Redaelli; Marianne Schmid Daners; Vartan Kurtcuoglu; Filippo Consolo; Diane de Zélicourt
Journal:  Front Cardiovasc Med       Date:  2022-03-11