Review: Clinical usefulness of ultrapure dialysate--recent evidence and perspectives.

Ikuto Masakane1.   

Abstract

It has generally been accepted that biological contamination of dialysate deteriorates the biocompatibility of dialysis therapy and accelerates dialysis-related complications such as dialysis-related amyloidosis (DRA) and malnutrition-inflammation-atherosclerosis (MIA) syndrome. During the past decade several studies have clarified that very slight amounts of contamination can lead to inflammatory response, and we could not confirm biological dialysate quality only by measuring endotoxin levels despite of measuring viable cell counts or biofilms. To achieve this, the European Renal Association/European Dialysis Transplantation Association and the American National Standardization Institute/Association for the Advancement of Medical Instrumentation published new standards for dialysate, in which very strict control levels were recommended with regard to viable bacterial cell counts. In 2004 JSDT raised the required standard of the levels of endotoxin, and began to develop a standard for bacterial cell counts. In Japan, many chronic kidney disease patients are treated with centralized dialysate supply systems which have weak spots in disinfecting the system. This causes some difficulties in making a standard for viable bacterial cell counts. In the present paper, we summarize evidences of clinical usefulness of ultrapure dialysate and perspectives of the standard for dialysate in Japan.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16911188     DOI: 10.1111/j.1744-9987.2006.00388.x

Source DB:  PubMed          Journal:  Ther Apher Dial        ISSN: 1744-9979            Impact factor:   1.762


  5 in total

Review 1.  Renal replacement therapy review: past, present and future.

Authors:  Geoffrey M Fleming
Journal:  Organogenesis       Date:  2011-01-01       Impact factor: 2.500

Review 2.  Hemodialysis and water quality.

Authors:  Angela D Coulliette; Matthew J Arduino
Journal:  Semin Dial       Date:  2013 Jul-Aug       Impact factor: 3.455

Review 3.  Oxidative Stress in Hemodialysis Patients: A Review of the Literature.

Authors:  Vassilios Liakopoulos; Stefanos Roumeliotis; Xenia Gorny; Evangelia Dounousi; Peter R Mertens
Journal:  Oxid Med Cell Longev       Date:  2017-09-12       Impact factor: 6.543

4.  Haemodiafiltration-optimal efficiency and safety.

Authors:  Ingrid Ledebo; Peter J Blankestijn
Journal:  NDT Plus       Date:  2009-11-05

5.  High-quality dialysis: a lesson from the Japanese experience: Effects of membrane material on nutritional status and dialysis-related symptoms.

Authors:  Ikuto Masakane
Journal:  NDT Plus       Date:  2010-05