Literature DB >> 16908225

Determination of metolazone in human blood by liquid chromatography with electrospray ionization tandem mass spectrometry.

Guangli Wei1, Shuhua Xiao, Changxiao Liu.   

Abstract

A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16908225     DOI: 10.1016/j.jchromb.2006.07.033

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Pharmacokinetic study of single- and multiple-dosing with metolazone tablets in healthy Chinese population.

Authors:  Xueqing Li; Rutao Wang; Yang Liu; Yun Liu; Heng Zheng; Yabo Feng; Na Zhao; Hongbin Geng; Wanzhi Zhang; Aidong Wen
Journal:  BMC Pharmacol Toxicol       Date:  2017-11-16       Impact factor: 2.483

2.  Stability-Indicating Spectrofluorimetric Methods for the Determination of Metolazone and Xipamide in Their Tablets. Application to Content Uniformity Testing.

Authors:  M I Walash; N El-Enany; M I Eid; M E Fathy
Journal:  J Fluoresc       Date:  2013-10-04       Impact factor: 2.217

3.  Validated RP-HPLC Method for Simultaneous Quantitation of Losartan Potassium and Metolazone in Bulk Drug and Formulation.

Authors:  Ramkumar Dubey; Vidhya K Bhusari; Sunil R Dhaneshwar
Journal:  Sci Pharm       Date:  2011-06-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.