Literature DB >> 16906503

Multiparallel chiral method development screening using an 8-channel microfluidic HPLC system.

Peter Sajonz1, Xiaoyi Gong, William R Leonard, Mirlinda Biba, Christopher J Welch.   

Abstract

The Eksigent Express 800 8-channel microfluidic HPLC system was investigated for carrying out multiparallel screening and development of fast normal phase chiral separations. In contrast to the familiar automated sequential chiral method development approaches that often afford a next day result, the multiparallel approach offers the exciting possibility of near "real time" method development, often affording an optimized method in less than 1 h. In this study, four column types (300 microm i.d.) with two different mobile phases are screened using a universal standard gradient approach. Interestingly, parallel method optimization following initial screening was shown to sometimes lead to surprising and unanticipated outcomes, emphasizing the value of the multiparallel screening approach. A variety of standard test racemates were analyzed, with optimized separation methods for most in the 1- to 2-min range. These results compare favorably with results obtained on a single channel conventional HPLC system using 4.6-mm i.d. columns. In addition, isocratic methods developed on the microbore columns are readily translated to the larger column format. (c) 2006 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2006        PMID: 16906503     DOI: 10.1002/chir.20325

Source DB:  PubMed          Journal:  Chirality        ISSN: 0899-0042            Impact factor:   2.437


  3 in total

1.  Monolithic porous polymer stationary phases in polyimide chips for the fast high-performance liquid chromatography separation of proteins and peptides.

Authors:  Pavel A Levkin; Sebastiaan Eeltink; Thomas R Stratton; Reid Brennen; Karla Robotti; Hongfeng Yin; Kevin Killeen; Frantisek Svec; Jean M J Fréchet
Journal:  J Chromatogr A       Date:  2008-03-15       Impact factor: 4.759

2.  From Substituent Effects to Applications: Enhancing the Optical Response of a Four-Component Assembly for Reporting EE Values.

Authors:  Chung-Yon Lin; Michael W Giuliano; Bryan D Ellis; Scott J Miller; Eric V Anslyn
Journal:  Chem Sci       Date:  2016-03-07       Impact factor: 9.825

3.  Advantages and Pitfalls of Capillary Electrophoresis of Pharmaceutical Compounds and Their Enantiomers in Complex Samples: Comparison of Hydrodynamically Opened and Closed Systems.

Authors:  Marián Masár; Jasna Hradski; Martin G Schmid; Roman Szucs
Journal:  Int J Mol Sci       Date:  2020-09-18       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.