Literature DB >> 16906068

Cemented rotating hinge endoprosthesis for limb salvage of distal femur tumors.

Sanjeev Sharma1, Robert E Turcotte, Marc H Isler, Cindy Wong.   

Abstract

UNLABELLED: We retrospectively ascertained the outcomes and complications with a cemented rotating hinge implant. Implant failure was defined as amputation of the affected limb and revision of part or all of the components. We included 77 consecutive distal femoral replacements performed between 1989 and 2004. The mean age was 42 years (range, 12-87 years) and the mean length of followup was 52 months (range, 1.5-157 months). Five-year implant survival was 84% and 10-year survival was 79%. There were 67 bone sarcomas, two soft tissue sarcomas and eight metastatic carcinomas. At followup, 54 patients had no evidence of disease, 16 were alive with disease, and seven were dead from disease. Six patients had deep infection, two of which required amputations. There were five local recurrences; three needed amputation and two soft-tissue excisions only. Three patients sustained a tibial bearing fracture and one required replacement of loose bumper. No revision was performed for stem loosening, stem fracture, or bushing wear. Musculoskeletal Tumor Society 1987 scores averaged 30 and Toronto Extremity Salvage Scores averaged 77.6 at latest followup. Cemented endoprosthesis is a reliable procedure after resection of the distal femur for tumors. LEVEL OF EVIDENCE: Therapeutic study, level IV (case series).

Entities:  

Mesh:

Year:  2006        PMID: 16906068     DOI: 10.1097/01.blo.0000229316.66501.fc

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  [Megaprostheses of the knee joint].

Authors:  K Anagnostakos; D Kohn
Journal:  Orthopade       Date:  2010-10       Impact factor: 1.087

2.  Revision of broken knee megaprostheses: new solution to old problems.

Authors:  Manish Agarwal; Ashish Gulia; B Ravi; Rupesh Ghyar; Ajay Puri
Journal:  Clin Orthop Relat Res       Date:  2010-11       Impact factor: 4.176

3.  Joint-sparing or physeal-sparing diaphyseal resections: the challenge of holding small fragments.

Authors:  Manish Agarwal; Ajay Puri; Ashish Gulia; Kishore Reddy
Journal:  Clin Orthop Relat Res       Date:  2010-11       Impact factor: 4.176

4.  Radiographic assessment of distal femur cemented stems in tumor endoprostheses.

Authors:  R E Turcotte; N A Stavropoulos; J Toreson; M Alsultan
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-28

5.  Perioperative infection rate in patients with osteosarcomas treated with resection and prosthetic reconstruction.

Authors:  Xin Li; Vincent M Moretti; Adedayo O Ashana; Richard D Lackman
Journal:  Clin Orthop Relat Res       Date:  2011-05-12       Impact factor: 4.176

6.  Survival, complications and functional outcomes of cemented megaprostheses for high-grade osteosarcoma around the knee.

Authors:  Chunlin Zhang; Jianping Hu; Kunpeng Zhu; Tao Cai; Xiaolong Ma
Journal:  Int Orthop       Date:  2018-02-09       Impact factor: 3.075

7.  The linea aspera as a rotational landmark: an anatomical MRI-based study.

Authors:  Gustavo Reple; Arnaud Felden; Antoine Feydy; Philippe Anract; David Biau
Journal:  Surg Radiol Anat       Date:  2016-03-12       Impact factor: 1.246

8.  Distal femur reconstruction with modular tumour prostheses: a single Institution analysis of implant survival comparing fixed versus rotating hinge knee prostheses.

Authors:  Elisa Pala; Giulia Trovarelli; Andrea Angelini; Pietro Ruggieri
Journal:  Int Orthop       Date:  2016-06-04       Impact factor: 3.075

9.  Compressive osseointegration of tibial implants in primary cancer reconstruction.

Authors:  Richard J O'Donnell
Journal:  Clin Orthop Relat Res       Date:  2009-08-04       Impact factor: 4.176

10.  Cemented distal femoral endoprostheses for musculoskeletal tumor: improved survival of modular versus custom implants.

Authors:  Adam J Schwartz; J Michael Kabo; Fritz C Eilber; Frederick R Eilber; Jeffrey J Eckardt
Journal:  Clin Orthop Relat Res       Date:  2009-12-22       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.