Abstract

PURPOSE: The goal of this descriptive study was to investigate the anatomy of the carpal tunnel with respect to the related neurovascular structures, because a detailed knowledge of the complex anatomy of this region is essential to perform endoscopic carpal tunnel release.
METHODS: Sixteen fresh-frozen cadaveric hands were used for the study. Dissection of the palmar aspect of the hand was performed by use of magnifying loupes, an operative microscope, and microsurgical instruments. All anatomic components were photographed, and dimensions were recorded by use of a micrometer. The distance from the radial aspect of the os pisiformis and the proximal and distal portals to the main structures that may be injured was measured. Topography of the transverse ligament and possible adhesions to the tendons and median nerve were also recorded.
RESULTS: The mean distance from the radial aspect of the os pisiformis to the radial border of Guyon's canal and the ulnar edge of the palmaris longus tendon was 10.3 mm (range, 9 to 12 mm) and 16.1 mm (range, 12 to 22 mm), respectively. The mean distance from the distal portal to the superficial palmar arch and the ulnar artery was 10.4 mm (range, 5 to 15 mm) and 7.6 mm (range, 4.5 to 9 mm), respectively. The mean distance from the distal edge of the transverse ligament to the thenar branch of the median nerve was 2.7 mm (range, 0 to 4.1 mm). The mean length of the transverse ligament was 31 mm (range, 25 to 34.5 mm). In 14 hands we also identified the palmaris longus tendon. In 11 hands we found adhesions between the transverse ligament and the sheath of the flexor tendons.
CONCLUSIONS: The palmaris longus can be used as a guide for the placement of the proximal portal. Staying at the ulnar side of the palmaris longus keeps the superficial palmar branch of the median nerve at a safe distance from the instruments. The "fat drop sign" is also a useful guide for the placement of the distal margin of the transverse carpal ligament, keeping the distal portal away from the superficial palmar arch. Synovial adhesions can usually cover the inferior surface of the transverse ligament, and they need to be removed for clear endoscopic identification of the transverse fibers before the ligament is cut. CLINICAL RELEVANCE: Detailed knowledge of the complex anatomy of the carpal tunnel is essential to perform endoscopic carpal tunnel release.

Entities:  

Mesh:

Year:  2006        PMID: 16904575     DOI: 10.1016/j.arthro.2006.03.021

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  7 in total

1.  Single portal endoscopic carpal tunnel release: modification of Menon's technique and data from 65 cases.

Authors:  Alvin Chao-Yu Chen; Meng-Huang Wu; Chung-Hsun Chang; Chun-Ying Cheng; Kuo-Yau Hsu
Journal:  Int Orthop       Date:  2010-05-05       Impact factor: 3.075

2.  The Clinical Application of Kaplan's Cardinal Line as a Surface Marker for the Superficial Palmar Arch.

Authors:  Anand P Panchal; Marc A Trzeciak
Journal:  Hand (N Y)       Date:  2009-10-06

Review 3.  A handy review of carpal tunnel syndrome: From anatomy to diagnosis and treatment.

Authors:  Mohammad Ghasemi-Rad; Emad Nosair; Andrea Vegh; Afshin Mohammadi; Adam Akkad; Emal Lesha; Mohammad Hossein Mohammadi; Doaa Sayed; Ali Davarian; Tooraj Maleki-Miyandoab; Anwarul Hasan
Journal:  World J Radiol       Date:  2014-06-28

4.  'INSIGHT-PRECISION': a new, mini-invasive technique for the surgical treatment of carpal tunnel syndrome.

Authors:  José Dinis Carmo
Journal:  J Int Med Res       Date:  2019-10-20       Impact factor: 1.671

5.  A Cadaveric Study of the Carpal Tunnel and Anatomical Variations of the Median Nerve in Vietnamese Adults: Implications for Single Portal Endoscopic Carpal Tunnel Release.

Authors:  N T Ma; T D Tran; Q Tran; M C Duong
Journal:  Malays Orthop J       Date:  2022-03

Review 6.  Endoscopic and Open Release Similarly Safe for the Treatment of Carpal Tunnel Syndrome. A Systematic Review and Meta-Analysis.

Authors:  Haris S Vasiliadis; Adriani Nikolakopoulou; Ian Shrier; Michael P Lunn; Ruth Brassington; Rob J P Scholten; Georgia Salanti
Journal:  PLoS One       Date:  2015-12-16       Impact factor: 3.240

7.  Functional Outcomes of 300 Carpal Tunnel Release: 1.5 cm Longitudinal Mini-incision.

Authors:  Keykhosro Mardanpour; Mahtab Rahbar; Sourena Mardanpour
Journal:  Asian J Neurosurg       Date:  2019 Jul-Sep