Literature DB >> 16904553

Effects of cocaine intoxication on the threshold for stun gun induction of ventricular fibrillation.

Dhanunjaya Lakkireddy1, Donald Wallick, Kay Ryschon, Mina K Chung, Jagdish Butany, David Martin, Walid Saliba, William Kowalewski, Andrea Natale, Patrick J Tchou.   

Abstract

OBJECTIVES: This study sought to assess cocaine's effects on Taser-induced ventricular fibrillation (VF) threshold in a pig model.
BACKGROUND: Stun guns are increasingly used by law enforcement officials to restrain violent subjects, who are frequently intoxicated with cocaine and other drugs of abuse. The interaction of cocaine and the stun gun on VF induction is unknown.
METHODS: We tested five adult pigs using a custom device built to deliver multiples of standard neuromuscular incapacitating (NMI) discharge that matched the waveform of a commercially available electrical stun gun (Taser X-26, Taser International, Scottsdale, Arizona). The NMI discharges were applied in a step-up and step-down fashion at 5 body locations. End points included determination of maximum safe multiple, minimum VF-inducing multiple, and ventricular fibrillation threshold (VFT) before and after cocaine infusion.
RESULTS: Standard NMI discharges (x1) did not cause VF at any of the 5 locations before or after cocaine infusion. The maximum safe multiple, minimum VF-inducing multiple, and VFT of NMI application increased with increasing electrode distance from the heart. There was a 1.5- to 2-fold increase in these values at each position after cocaine infusion, suggesting decreased cardiac vulnerability for VF. Cocaine increased the required strength of NMI discharge that caused 2:1 or 3:1 ventricular capture ratios at all of the positions. No significant changes in creatine kinase-MB and troponin-I were seen.
CONCLUSIONS: Cocaine increased the VFT of NMI discharges at all dart locations tested and reduced cardiac vulnerability to VF. The application of cocaine increased the safety margin by 50% to 100% above the baseline safety margin.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16904553     DOI: 10.1016/j.jacc.2006.03.055

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  TASER safety.

Authors:  Mark W Kroll; Hugh Calkins; Richard M Luceri; Michael A Graham; William G Heegaard
Journal:  CMAJ       Date:  2008-09-23       Impact factor: 8.262

Review 2.  Cardiac stimulation with high voltage discharge from stun guns.

Authors:  Kumaraswamy Nanthakumar; Stephane Massé; Karthikeyan Umapathy; Paul Dorian; Elias Sevaptsidis; Menashe Waxman
Journal:  CMAJ       Date:  2008-05-01       Impact factor: 8.262

Review 3.  Repeated or long-duration TASER electronic control device exposures: acidemia and lack of respiration.

Authors:  James R Jauchem
Journal:  Forensic Sci Med Pathol       Date:  2010-03       Impact factor: 2.007

Review 4.  Cardiac and skeletal muscle effects of electrical weapons : A review of human and animal studies.

Authors:  Sebastian N Kunz; Hugh Calkins; Jiri Adamec; Mark W Kroll
Journal:  Forensic Sci Med Pathol       Date:  2018-06-28       Impact factor: 2.007

5.  An evaluation of two conducted electrical weapons and two probe designs using a swine comparative cardiac safety model.

Authors:  Donald Murray Dawes; Jeffrey D Ho; Johanna C Moore; James R Miner
Journal:  Forensic Sci Med Pathol       Date:  2013-03-30       Impact factor: 2.007

6.  Cardiac fibrillation risk of TASER X-26 dart mode application.

Authors:  Norbert Leitgeb; Florian Niedermayr; Gerhart Loos; Robert Neubauer
Journal:  Wien Med Wochenschr       Date:  2011-11-08

7.  Radiofrequency ablation of drug refractory ventricular tachycardia related to cocaine use: a feasibility, safety, and efficacy study.

Authors:  Dhanunjaya Lakkireddy; Arun Kanmanthareddy; Mazda Biria; Yeruva Madhu Reddy; Jayasree Pillarisetti; Srijoy Mahapatra; Loren Berenbom; Larry Chinitz; Donita Atkins; Sudharani Bommana; Roderick Tung; Luigi DI Biase; Kalyanam Shivkumar; Andrea Natale
Journal:  J Cardiovasc Electrophysiol       Date:  2014-05-30

8.  Electromuscular incapacitating devices discharge and risk of severe bradycardia.

Authors:  Stepan Havranek; Petr Neuzil; Ales Linhart
Journal:  Am J Forensic Med Pathol       Date:  2015-06       Impact factor: 0.921

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.