Literature DB >> 16902339

Low incidence of subdural grid-related complications in prolonged pediatric EEG monitoring.

Wael Musleh1, Reza Yassari, Kurt Hecox, Michael Kohrman, Maria Chico, David Frim.   

Abstract

Invasive EEG monitoring is one of the best tools available for localization of epileptogenic foci in the brain. However, published data in mixed series of adult and pediatric patients show high incidence of epidural bacterial contamination, cerebrospinal fluid leakage, and skin infection after subdural electrode implantation. We sought to determine whether the complication rate from prolonged subdural electrode implantation would be lower in a purely pediatric series. Thirty-three subdural electrode implantation procedures were performed in 29 pediatric patients (age range 4-19) for an average of 7.2 days (range 3-14 days). Electrode number varied from 32 to >128 with a range of 4-11 electrode wires piercing the skin >1 cm from the primary incision. Of the 33 implantations and resections (66 craniotomies), 5 were for reimplantation. There were no permanent complications related to grid implantation. Transient complications included 1 case of prolonged prothrombin time and 1 patient with unexplained fever, both of which resolved upon removal of the grids. There were two culture-positive infections, one epidural and one superficial, both in patients undergoing reimplantation. There was no percutaneous cerebrospinal fluid leakage noted and no operation was aborted due to bleeding caused by grid placement. Our data suggest that subdural grid implantation in children is remarkably safe even for prolonged implantation, though infectious risk is significantly higher in reoperation (p = 0.019). This observation may contribute to lowering the threshold for two-stage invasive monitoring approaches in children with epilepsy. Copyright 2006 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16902339     DOI: 10.1159/000094063

Source DB:  PubMed          Journal:  Pediatr Neurosurg        ISSN: 1016-2291            Impact factor:   1.162


  6 in total

Review 1.  Magnetoencephalography for pediatric epilepsy: how we do it.

Authors:  E S Schwartz; D J Dlugos; P B Storm; J Dell; R Magee; T P Flynn; D M Zarnow; R A Zimmerman; T P L Roberts
Journal:  AJNR Am J Neuroradiol       Date:  2008-02-13       Impact factor: 3.825

2.  A comprehensive analysis of early outcomes and complication rates after 769 craniotomies in pediatric patients.

Authors:  M von Lehe; H-J Kim; J Schramm; M Simon
Journal:  Childs Nerv Syst       Date:  2012-12-30       Impact factor: 1.475

3.  Surgery after intracranial investigation with subdural electrodes in patients with drug-resistant focal epilepsy: outcome and complications.

Authors:  Roberta Morace; Giancarlo Di Gennaro; Angelo Picardi; Pier Paolo Quarato; Antonio Sparano; Addolorata Mascia; Giulio Nicolò Meldolesi; Liliana Graciela Grammaldo; Marco De Risi; Vincenzo Esposito
Journal:  Neurosurg Rev       Date:  2012-03-22       Impact factor: 3.042

4.  An unusual complication of invasive video-EEG monitoring: subelectrode hematoma without subdural component: case report.

Authors:  Gokhan Bozkurt; Selim Ayhan; Nese Dericioglu; Serap Saygi; Nejat Akalan
Journal:  Childs Nerv Syst       Date:  2010-08       Impact factor: 1.475

5.  Complications to invasive epilepsy surgery workup with subdural and depth electrodes: a prospective population-based observational study.

Authors:  Emelie Hedegärd; Johan Bjellvi; Anna Edelvik; Bertil Rydenhag; Roland Flink; Kristina Malmgren
Journal:  J Neurol Neurosurg Psychiatry       Date:  2013-11-29       Impact factor: 10.154

6.  Methodology, outcome, safety and in vivo accuracy in traditional frame-based stereoelectroencephalography.

Authors:  Lars E van der Loo; Olaf E M G Schijns; Govert Hoogland; Albert J Colon; G Louis Wagner; Jim T A Dings; Pieter L Kubben
Journal:  Acta Neurochir (Wien)       Date:  2017-07-05       Impact factor: 2.216

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.